+7 (812) 929-8183,
+7 (812) 929-8283

Cambium Networks Software Release 2.5.1

RELEASE SOFTWARE

The following software update is provided with ePMP System Release 2.5.1:

Connectorized Radio with Sync ePMP-GPS_Synced-v2.5.1.tar.gz

Integrated Radio / Connectorized Radio ePMP-NonGPS_Synced-v2.5.1.tar.gz

CNUT package (for all radios) ePMP-2.5.1.pkg3

NEW LOCAL IP

Prior to System Release 2.1, in both Bridge and NAT mode, the ePMP Device was previously accessible through a local IP of 10.1.1.254 through the LAN port. Beginning with System Release 2.1, the local IP has been updated to 169.254.1.1(/16).

EPMP POST-­UPGRADE IP ADDRESSING

If Device IP address Mode is set to DHCP and the device is unable to retrieve IP address information via DHCP, the device management IP is set to fallback IP of 192.168.0.1 (AP mode), 192.168.0.2 (SM mode), 192.168.0.3 (Spectrum Analyzer mode) or a previously configured static Device IP Address. Units can always be accessed via the Ethernet port with a local IP of 169.254.1.1.

System Release 2.5.1 includes the following:

Defect fixes

  • Changed the OID numbers for cambiumAPConnectedSTAEntry table back to what they were in releases prior to 2.5.
  • Fixed crash on SM when using 2.5ms frame when SM is under heavy interference.
  • Fixed issue where SMs take longer than normal to register to AP when using 2.5ms frame size.
  • Fixed issue where, when AP is in Standard WiFi mode and using 5.2 GHz, it incorrectly uses 33 dBm EIRP instead of 36 dBm in FCC regions.
  • Fixed issue where 2.4 GHz AP will not use more than 20 dBm TX power when in Standard WiFi mode.
  • Fixed issue where ping utility (under Tools->Ping) will not work if buffer size is larger than 1472 bytes.
  • Fixed occasional SM registration issue with Reason: INVALID SECURITY KEY in PTP TDD and ePTP modes.
  • Fixed RFC1213 OID .1.3.6.1.2.1.2.2.1.5.1 (ifSpeed) always returning “10000000" regardless of what the speed is configured/negotiated to.
  • Fixed a rare issue where, in ePTP mode, the radio would stop transmitting data after a few days of normal operation, requiring a reboot.
  • Fixed a security vulnerability on ePMP radios that are exposed to the open internet when using white IP addresses.

cnMaestro™ support

This release supports management of ePMP radios using cnMaestro™, Cambium Networks' new management platform, although its support of ePMP devices is still considered a beta feature. APs and SMs can be managed.

This release supports the following new ePMP™ products:

  • ePMP™ GPS Sync Access Point (AP) Lite
  • ePMP™ Force 180 5 GHz subscriber module
  • ePMP™ Force 200 2.4 GHz subscriber module

The ePMP GPS Sync AP Lite includes ePMP’s GPS Synchronization technology and can connect up to 10 subscriber modules. Ideal for low-density environments, this model lowers network operators’ initial deployment costs and improves spectral efficiency while mitigating interference between access points (APs) and subscriber modules (SMs).

Key features of ePMP GPS Sync AP Lite Include:

  • Frequency: 5 GHz
  • Throughput: up to 200 Mbps
  • Configuration: point-to-multipoint or point-to-point
  • Full expansion to 120 SMs connectivity through license key purchase

The ePMP Force 180 5 GHz subscriber module is the next generation of the ePMP 5 GHz Integrated Radio, improving upon its predecessor with a higher-gain, integrated patch antenna.

Key features of ePMP Force 180 5 GHz subscriber module include:

  • Frequency: 5 GHz
  • Throughput: up to 200 Mbps
  • Range: up to 20 kilometers
  • Configuration: point-to-multipoint
  • 16 dBi antenna
  • Gigabit Ethernet port
  • Adjustable mounting bracket
  • Compatibility with standard PoE pinouts to facilitate inclusion of ePMP in existing network architectures
  • Horizontal mount with a narrower beam width minimizing impact of interference

The ePMP Force 200 2.4 GHz adds a subscriber module and point-to-point (PTP) radio to ePMP’s 2.4 GHz line of products.

Key features of ePMP Force 200 2.4 GHz include:

  • Frequency: 2.4 GHz
  • Throughput: up to 200 Mbps
  • Range: up to 40 kilometers
  • Configuration: point-to-point
  • Optional radome cover

Software Release 2.5.1:

ePMP 1000 HotSpot Software Release 1.0:

Known problems or limitations (System Release 2.5)

Tracking Description / Workaround
10380 On occasion upon boot up, AP sends DHCP request on the wireless interface in addition to the Ethernet interface. (Resolved in 2.5.1)
10371 2.4 GHz AP will not use more than 20 dBm TX power when in Standard WiFi mode. (Resolved in 2.5.1)
10363 RFC1213 OID .1.3.6.1.2.1.2.2.1.5.1 (ifSpeed) always returning "10000000" regardless of what the speed is configured/negotiated to. (Resolved in 2.5.1)
10344 OID numbers for cambiumAPConnectedSTAEntry table incremented by 1 in Release 2.5. (Resolved in 2.5.1)
10332 SMs take longer than normal to register to AP when using 2.5ms frame size. (Resolved in 2.5.1)
10326 When AP is in Standard WiFi mode and using 5.2 GHz, it incorrectly uses 33 dBm EIRP instead of 36 dBm in FCC regions. (Resolved in 2.5.1)
10321 Ping utility (under Tools->Ping) will not work if buffer size is larger than 1472 bytes. (Resolved in 2.5.1)
10301 When in ePTP mode, the radio would stop transmitting data after a few days of normal operation, requiring a reboot. (Resolved in 2.5.1)
10283 In Flexible mode, when sending bidirectional TCP data, the throughput may degrade up to 17% on the Uplink compared to previous releases. (Resolved in 2.5.1)
10276 When an ePMP SM is switched to Standard WiFi mode, the "Distance To AP" under Configuration->Radio incorrectly gets set to 52 miles. Workaround is to manually adjust this parameter to the correct distance of SM to the AP.
10273 SMs occasionally do not register issue with Reason: INVALID SECURITY KEY in PTP TDD and ePTP modes. (Resolved in 2.5.1)
10271 When the SM is in ePTP or Standard WiFi mode, the web interface incorrectly displays "Subscriber Module Priority" field. SM Priority is supported in TDD mode only and this issue has no impact on the normal operation of the system.
10110
10108
On rare occasion, SM crashes when using 2.5ms frame when the SM is under heavy interference. (Resolved in 2.5.1)
5405 ePMP radios may be exposed to the open internet when using white IP addresses. This makes the radio vulnerable to attacks. (Resolved in 2.5.1)

Known problems or limitations (System Release 2.4.3)

Tracking Description / Workaround
10127 On occasion, multicast traffic may not be forwarded by the AP on the downlink. (Resolved in 2.5)
10099 When the AP is SNMP polled for the list of registered SMs, the SNMP agent returns an empty string until the web interface is pulled up. (Resolved in 2.5)
10060 When special characters such as apostrophes are used in Device Name, System Name and System Description fields and spaces are used in AP SSID field, upgrade from 2.4.2 to 2.4.3 results in configuration errors. Field validation checks have been added to the web interface to warn the users of invalid special characters for the impacted fields. (Resolved in 2.5)
10032 When Separate Management IP is enabled and the SM is configured as a PPPoE client, it is possible to access the management interface of the SM through its Wireless IP. (Resolved in 2.5)
9911 List of available frequencies for country code Thailand is incorrect. (Resolved in 2.5)
9893 The transmitter output power displayed by the GUI varies significantly as the radio switches between management and data packets to take power measurements. (Resolved in 2.5)
9837 On release 2.4.3, the AP will not allow more than 106 SMs to register to it. (Resolved in 2.5)
9808 After changing the IP address of the ePMP radio, the GUI does not auto reconnect to the device using the new IP. As a workaround, type in the new IP address on the web browser to access the radio's GUI. (Resolved in 2.5)
9655 When in ePTP and after several days of the link being up and functioning normally, the ePTP Slave may stop passing user traffic. (Resolved in 2.5)
9376 On occasion, when changing parameters under Configuration->Network (and Saving), the device may take up to 60 seconds to apply the changes. (Resolved in 2.5)
9333 On the GUI, where the page has internal vertical scroll bars (ex: Monitor->Performance), the table may overlap the page footer. There is no impact to normal operation of the system. (Resolved in 2.5)

Known problems or limitations (System Release 2.4.2)

Tracking Description / Workaround
9283 On the Connectorized radio with Sync supporting GigE port speeds where the Radio Mode is an AP and Ethernet Port Setting is set to manual/1000Mbps; then if the Radio Mode is switched to SM, the port speed will default to 100Mbps. Pleas ensure that after changing the Radio Mode to SM, the port speed is set to 1000Mbps. (Resolved in 2.5)
9255 On rare occasions, when an SM reregisters, the Network Entry Attempts counter under Monitor->Performance page will show twice the number of actual NE attempts. (Resolved in 2.5)

Known problems or limitations (System Release 2.4.1)

Tracking Description / Workaround
9290 On a json config import using Firefox, if the Device Name has a space, the config import fails. (Resolved in 2.4.2)

Known problems or limitations (System Release 2.4)

Tracking Description / Workaround
9238 Bridge table on the SM under Monitor->Network displays "NA" under Port for certain entries. (Resolved in 2.4.2)
9267 When the radio is in TDD mode, the "show rssi" command provides no results. (Resolved in 2.4.2)
9146 When performing an SNMP get on the MIR Profile Names, the last character is truncated. (Resolved in 2.4.1)
9041 Software/Upgrade downgrade fails when using the HTTPS under the URL option under Tools->Software Upgrade. (Resolved in 2.4.1)
8990 CNUT upgrade fails when trying to upgrade from Release 2.4. (Resolved in 2.4.1)
8987 When operating in ePTP mode, the Slave displays the Operating Frequency 10 MHz lower than the actual operating frequency. (Resolved in 2.4.1)
8967 Available AP List under Monitor->Wireless on the SM is no longer displayed. In addition, on occasion, the Bridge Table does not display any devices connected to the LAN port of the SM. (Resolved in 2.4.1)
8959 It is not possible to use the '-' symbol when configuring the SSID through CLI. (Resolved in 2.4.1)
8893 On occasion, when changing from ePTP to TDD, the GUI may display incorrect values (ex: Country Code and Frequency Carrier) after the change is saved. Workaround is to refresh the browser window to reload correct values. (Resolved in 2.4.3)
8820 When changing modes from ePTP Master to SM TDD, the device may incorrectly boot up as ePTP Slave after the change is saved. Workaround is to change from ePTP Master to AP TDD mode and then switch to SM TDD mode. (Resolved in 2.4.3)
8732 When an SM is not registered to an AP, eAlign (under Tools->eAlign) incorrectly displays an RSSI value. Ignore the measurement until a valid link is established. (Resolved in 2.4.3)
8690 eAlign not available on the AP when operating as an Enhanced PTP Master. This functionality will be added in a near future release. (Resolved in 2.4.3)
8578 On rare occasion, when the GUI of the ePMP radio is opened in Google Chrome and left inactive for a few hours, the browser loses connectivity with the radio and hangs. Workaround is to close the browser window/tab and open a fresh GUI session. (Resolved in 2.5)
8532 On rare occasion, when the GUI of the ePMP radio is open and left inactive for four or more hours, a java scripts error occurs and the GUI becomes unresponsive. Workaround is to close the browser window/tab and open a fresh GUI session. (Resolved in 2.4.3)
8321 Separate Management IP is not accessible from the AP on the same subnet if a Separate Management Gateway is configured. (Resolved in 2.4.1)
8198 On occasion, stale ARP entries are not cleared from the ARP table (under Monitor->network) on the SM. The entries should be cleared in 5 minutes but it may take up to 10 minutes for them to be cleared.

Known problems or limitations (System Release 2.3.4)

Tracking Description / Workaround
8147 When SM is in Bridge mode, the Separate Management IP and Separate Management VLAN configurations are available on the GUI under Configuration->Network. There is no system impact due to this. (Resolved in 2.4.1)

Known problems or limitations (System Release 2.3.3)

Tracking Description / Workaround
8285 On rare occasions, it may not be possible to change the Synchronization Source under Configuration->Radio after upgrading the AP to 2.3.3. This is a GUI issue; the radio still operates normally using the previously chosen Synchronization Source. Workaround is to reboot the AP and reload the GUI on the browser. (Resolved in 2.3.4)
8063 When both the SM's Wireless IP and Separate Wireless Management IP are in the same subnet, then if both Data VLAN and Separate Wireless Management VLAN are the same, the SM's management interface is not accessible. As a workaround, please ensure that the two Wireless IPs are not on the same subnet and VLAN. (Resolved in 2.4.3)
8025 The management interface (GUI, ssh, SNMP etc.) of the AP is accessible only from within the same subnet as the AP. (Resolved in 2.3.3)
8011 When Separate Wireless Management IP is enabled and the SM's Wireless IP is obtained via DHCP, then the SM is accessible through the SM's Wireless IP. (Resolved in 2.3.4)
7946 On rare occasions, if eDetect is run system wide (i.e. Detecting Device set to AP/SMs) followed by clicking the Reset Stats button under Monitor->Performance, the GUI may lock up. Workaround is to reboot the AP to gain access to the GUI again. (Resolved in 2.3.4)
7822 When the SM is in NAT mode, it's possible to configure the Separate Wireless Management IP in the same subnet as the IP of the SMs Ethernet/LAN interface. Care should be taken to configure the Separate Wireless Management IP on a different subnet for security.
7816 When Separate Wireless Management IP is enabled, L2 ACL rules may not work as expected. (Resolved in 2.3.4)
7729 When selecting an AP from the Available APs list to add to the Preferred APs list (under Monitor-Wireless), the WPA2 password popup box may incorrectly present multiple fields to enter password. Workaround is to enter the password in all the fields and click Apply. (Resolved in 2.4.3)

Known problems or limitations (System Release 2.3)

Tracking Description / Workaround
7887 When using a Cisco SPA-122 ATA device under the SM; then if the SM loses registration and connects back to the AP, a reboot of the Cisco device may be required to restore VoIP services. (Resolved in 2.4.1)
7675 If a Microsoft Window 8.1 PC is used as a client and DHCP option 82 is enabled on the AP, the client may not be able to obtain a lease from the DHCP server above the AP. Currently the only workaround is to disable DHCP Option 82 on the AP. (Resolved in 2.3.1)
7688 On ETSI locked radios if Automatic Channel Selection (ACS) is enabled and/or Alternate Channels (1 and/or 2) are selected, then if radio mode is changed from AP to SM, it may not be possible to change it back to AP. Workaround is to disable ACS and remove Alternate Frequencies (Configuration->Radio) in AP mode before changing it to SM or SA. If this is not done, the only way to recover the radio (to change it back to AP from SM) is to factory default the unit. (Resolved in 2.3.1)
7676 SM may not successfully obtain an IP address via DHCP if certain special characters (ex: parenthesis) are used in the Device Name of the SM.
7639 When the SM is operating in Standard WiFi mode, the SM Priority feature is not supported. However the SM GUI displays the SM priority level on the Home page when in Wi-Fi mode. There is no system impact due to this. (Resolved in 2.4.3)
7638 With the introduction of the Multicast feature in Release 2.3, new GUI parameters have been added. Under Monitor->Network on the SM a subsection called Multicast Status has been added that displays the number of multicast groups identified by the SM. This subsection is repeated on the same page as a blank subsection. There is no system impact due to this. (Resolved in 2.3.4)
7627 In Release 2.3, a minor enhancement was introduced where the user is able to select an AP from the SM's Available APs list (under Monitor->Wireless) and add it to the Preferred APs list (under Configuration->Radio). When adding an AP with Open security mode, the GUI incorrectly prompts for a WPA2 password. Workaround is to enter a blank password, then navigate to the Preferred APs list (under Configuration->Radio) and set the security mode for the AP to Open. (Resolved in 2.4.3)
7626 When there are multiple entries in the Available APs list (under Monitor->Radio) on the SM, a vertical and/or horizontal scroll bar is activated depending on browser resolution and size. When the GUI auto refreshes, these scroll bars snap back to the left (horizontal) and top (vertical) and user will have to scroll again. Workaround is to increase the Webpage Auto Update time to a higher value (under Configuration->System) to reduce the frequency of the snap. (Resolved in 2.4)
7622 In Release 2.3, a minor enhancement was introduced where the user is able to select an AP from the SM's Available APs list (under Monitor->Wireless) and add it to the Preferred APs list (under Configuration->Radio). However the user is able to add more than 16 entries while the Preferred APs list supports a maximum of 16 entries. User will need to manually delete entries in the Preferred APs list to not exceed 16 before the configuration can be saved.
7529
7706
On a DFS channel and in the presence of interference, especially under bidirectional traffic, SMs may disconnect and not connect back to the AP. Workaround is to reboot the AP. (Resolved in 2.3.1)
7289 On occasion, the GUI does not display data on the Monitor->Wireless Page. Workaround is to refresh/reload the browser.
7287 When ACS is run multiple times, the ACS chart (under Tools->ACS) may display prior results while the radio is operating on a channel selected by the last ACS run. Refresh the browser to see the latest chart.
7236 When using 5 MHz or 10 MHz channel bandwidths, latency is up to 20% higher compared to 20/40 MHz channel bandwidths. (Resolved in 2.3.1)
7122 When there are more than 10 SMs connected to an AP, single stream TCP throughput on the downlink can degrade up to 25% for a single SM. (Resolved in 2.3.1)

Known problems or limitations (System Release 2.2)

Tracking Description / Workaround
7088 It is recommended to save the configuration right after deleting an L3 ACL rule. If before saving the configuration, a new ACL rule is added or existing rule is modified, it may result in a corrupted configuration of the rules. (Resolved in 2.3)
7083 If an SM is configured to obtain an IP through DHCP, then if the SM is configured to Spectrum Analyzer mode, the device will attempt to obtain an IP address from a DHCP server through the LAN side. If there are no DHCP servers available, the device will fall back to its default Spectrum Analyzer IP of 192.168.0.3. This is not an issue if the SM was configured with a static IP address. (Resolved in 2.3)
7064 When an SM is scanning for APs, even if the scan bandwidth is set to 20MHz, the Home screen on the GUI displays 40MHz under Operating Channel Bandwidth. This is simply a GUI display error. In reality, the SM is scanning 20 MHz channels. (Resolved in 2.3)
7038 After an AP or SM is configured to Spectrum Analyzer mode, parameters that don't apply to AP or SM mode respectively are displayed. The incorrect display of the fields does not have any impact on the normal operation of the system. (Resolved in 2.4)

Known problems or limitations (System Release 2.1)

Tracking Description / Workaround
7113 When the SM IP is set to 172.16.252.0/21 address space, then the SM GUI is not accessible using Firefox (Mozilla) browser. Workaround is to use a different browser (ex: Internet Explorer, Google Chrome or Apple Safari). (Resolved in 2.3)
7101 On rare occasion, cambiumpmp80211 SMRegTrap(1.3.6.1.4.1.17713.21.0.11) may cause a trap flood. Workaround is to reboot the AP to stop the flood. (Resolved in 2.2)
7032 When the SessionTime OID (.3.6.1.4.1.17713.21.1.2.20.1.12.1) on the SM is polled through SNMP, it does not update unless the GUI of the SM is open. (Resolved in 2.2)
6919 When ACS is run multiple times in a row (under Tools->Automatic Channel Selection), the ACS graph may also show the scale on the X-axis incorrectly (40MHz instead of 20MHz). Refresh the browser screen (F5 in MS Windows) to get the correct chart for the last ACS run on that page.
6918 When ACS is run multiple times in a row (under Tools->Automatic Channel Selection), the ACS graph may display a primary frequency different from the frequency at which the radio is operating on. (Resolved in 2.4.3)
6916 After running ACS on a 40MHz channel, the primary frequency displayed on the ACS chart (under Tools->Automatic Channel Selection) will be offset from the operating frequency of the radio by 10MHz. There is no workaround and there is no impact on the normal operation of the radio. This is an ACS chart display issue. (Resolved in 2.2)
6915 When adding preferred APs on the SM under Configuration->Radio, the WPA2 PSK field is not highlighted as a required field. Please ensure you fill in the WPA2 key to allow the GUI to save the changes. (Resolved in 2.3.1)
6913
6626
Using 'snmpget' to obtain SNR values from the device returns an error. Workaround is to use 'snmpbulkget' or 'snmpwalk' to obtain the OID values and parse for specific OIDs. (Resolved in 2.2)
6872 On occasion, when both ACS and Carrier Sense (under Configuration->Radio) are enabled, some SMs may not register to the AP. Workaround is to disable ACS or Carrier Sense. (Resolved in 2.2)
6847 When the AP SSID is 32 characters long, the entire SSID is not displayed on the AP's GUI Home page. (Resolved in 2.3)
6801 When an ETSI license key is applied to an ePMP 5GHz ETSI locked radio, it may come up with "Generic ETSI" as country code. Perform a second reboot of the radio to load the license key.
6772 After selecting text in a text box on the UI, it is not possible to replace it with new text by typing over it; it instead appends the new text. The original text has to be deleted first before entering in the new text. (Resolved in 2.4.3)
6650
6564
6562
After a configuration file is backed up, it is possible to change the file to include invalid scan frequencies and empty MIR entries. Do not configure empty or invalid entries in the configuration file before importing back into the radio. (Resolved in 2.2)
6539 On occasion, when eDetect is run from the AP, the UI will appear to be stuck in "Running" state beyond the time configured for Detection Duration. Refresh the browser for the UI to display the correct state. (Resolved in 2.2)
6407 When a new user logs into the radio UI, notifications for the previously logged in user is visible. Workaround is to clear all notifications before logging out of the radio's UI.
5677 When logged in using "Home" user account, only the Monitor menu is available and the home user cannot change any configuration. Workaround is to use admin or installer account. (Resolved in 2.2)

Known problems or limitations (System Release 2.0.2)

Tracking Description / Workaround
6901 On occasion, when using SNMP to monitor the Tx/Rx bytes, the device stops updating the counters after a few hours. Workaround is to reboot the device. (Resolved in 2.1)
6752 On the SM, when all 20MHz and 40MHz frequencies in the scan list are selected and saved, the GUI returns an error and the save is unsuccessful. (Resolved in 2.1)
6444 After altering the order of the APs in the Preferred APs list (under Configuration->Radio), then saving this configuration results in a failed save. (Resolved in 2.1)

Known problems or limitations (System Release 2.0.1)

Tracking Description / Workaround
6636 For certain ETSI countries, the EIRP limit for 5.8GHz is not enforced. (Resolved in 2.0.2)
6558 An Integrated/Connectorized Radio used as AP may crash when more than 40 SMs are registered to in a high interference environment. (Resolved in 2.0.2)
6509 When country code is set to Germany and using 40 MHz channel bandwidth, it is not possible to configure 5855 MHz at a DFS alternate frequency (Resolved in 2.0.2)
6283 On Connectorized Radio with Sync, when GigE is configured then sporadic packet loss may be seen when the Ethernet cable length is longer than 45 meters. (Resolved in 2.0.2)
6311 On 2.4GHz radios, operator cannot set country code other than United States/FCC (Resolved in 2.0.1)
6245 When configuring L2 firewall rules and non-numeric values are used for setting the "EtherType" rule, the UI will not display the rule value. However, the rule is set on the radio and will work normally. (Resolved in 2.1)
6117 When a device's configuration is backed up and modifications are made to the Radius Server table, only the first table entry is validated when the modified configuration is restored onto a device. Care must be taken to enter valid entries into the Radius Server table when modifying the device configuration file (.json format). (Resolved in 2.1)
6101 On ETSI radios, if an invalid license key is entered, the radio will reset to factory default settings. Care must be taken to enter the exact key string obtained from Cambium licensing web-site and avoid modifying the license key before entering into the radio. (Resolved in 2.3)
5956 When 16 or more L2 ACL rules are configured and full syslog is enabled and the radio is overloaded with small packets of size less than 30 bytes, it may cause of reboot. The radio will recover by itself after the reboot. (Resolved in 2.1)
5798 On occasion, upon launching the UI of the radio in a browser, a red icon may appear on the "Configure" menu button indicating incorrect configuration. The icon will disappear on its own within 3 seconds. (Resolved in 2.1)
5018 On rare occasion, when using Radius and the SM is under poor RF conditions, re­authentication may fail. A device reboot may be required to perform Network Entry again.

Known problems or limitations (System Release 1.4.3/1.4.4)

Tracking Description / Workaround
5845 When configuring a DMZ IP address on a subnet different from the Device LAN IP address subnet, a reboot of the radio is required for the changes to take effect. (Resolved in 2.0)
5664 When more than 150 membership VLANs are configured on the ePMP SM, there may be a degradation in throughput on that SM. (Resolved in 2.1)
5467 Packet Byte counters under the Monitor->Performance page, are 32-bit instead of 64-bit. (Resolved in 2.0)
4948 During the first 2 minutes after an AP boot up or restart of wireless interface (when changing radio parameters such as Tx power, Center Frequency etc.), the Throughput Test tool will provide poor results on DL. Throughput Test will perform normally after this 2-minute period. (Resolved in 2.0)
5762 The antenna gain parameter of the 2.4 GHz Integrated module is locked at 13 dBi while it must be 11 dBi. (Resolved in 1.4.3)
5751
5746
When running a Throughput Test (Tools => Throughput Test) under high interference conditions, the SM disconnects. (Resolved in 1.4.3)

Known problems or limitations (System Release 1.4.0)

Tracking Description / Workaround
5933 FCC countries are limited to 13dBm of Max Tx power instead of 14dBm (Resolved in 1.4.4)
5848 Using power reset sequence or reset button to default the radio does not work after the first time. (Resolved in 1.4.4)
5683 On ePMP radios programmed for EU region, two reboots are required when switching device mode from AP to SM. (Resolved in 2.4)
  On ePMP radios programmed for EU region, when NAT mode is enabled on the SM, there is
5672 no management access to the SM from the AP. This does not impact user traffic through the link. (Resolved in 1.4.1)
5671 On rare occasion, after an upgrade from Release 1.3.4 to Release 1.4.0, the Country Code setting is not carried over and no channels are available for selection. (Resolved in 1.4.1)
5670 A password change for management user accounts does not get applied and the radio falls back to the default password. (Resolved in 1.4.1)
  With 25 or more SMs registered to the AP, GUI access to the AP will be slower than normal.
5509 This does not impact normal operation of the radio and there is no impact to user traffic in the sector. (Resolved in 2.0)
5621 Trace route tool does provide any indication on the GUI when a different subnet is unreachable. (Resolved in 2.0)
  In Spectrum Analyzer mode, some greyed out fields can still be configured. These fields are
5543 meant to be read-only so the user must not modify them when device mode is SA. (Resolved in 2.0)

Known problems or limitations (System Release 1.3.4)

Tracking Description / Workaround
4948 Spectrum Analyzer has small range of frequencies that cannot be scanned (5720-5730 MHz). This is seen only if you manually configure a scan range. (Resolved in 1.4.0)
4598 VoIP priority cannot be assigned to user defined QoS profiles. This does not impact assigning VoIP priority to the overall system. (Resolved in 1.4.0)

Known problems or limitations (System Release 1.2.3)

Tracking Description / Workaround
4538 When SM is set to NAT and local DHCP server is enabled, it is possible to provide a start and end IP address for the DHCP pool that is outside the IP address/mask of the LAN interface. Please verify that the start and end IP addresses are valid for the DHCP mask when configuring the local DHCP server. (Resolved in 2.0)
 
4582 Only one DNS server can be configured on the ePMP radio. Configuration of a secondary DNS server is not currently supported. (Resolved in 1.3.4)
4698 When entering a MIR profile, make sure a profile number is configured with it. It is possible to configure a profile without a profile number and this profile will not be usable in the system. (Resolved in 1.3.4)
4189 Configuring alternate DFS frequency is possible on a non-DFS (5.7GHz) band. This has no impact on the system operation.
4705 The DL RSSI level reported at the AP (Monitor->Wireless Status) is an estimated value. For accuracy, use the DL RSSI reported at the SM.
28.10.2015