
|
Прайс-лист Серверы HP
Overview
HP ProLiant DL160 Generation 6 (G6)
|
Hot Plug SAS/SATA and Non-Hot
Plug SATA Models |

|
 |
Front View: |
Rear View: |
1. |
Access panel |
1. |
Power Supply Cable Socket |
2. |
System fans |
2. |
Video Port |
3. |
Two USB ports |
3. |
Serial Port |
4. |
Power on/off & system LEDs |
4. |
Rear USB ports (2) |
5. |
Optional 3rd and 4th
3.5" Non-Hot plug SATA or hot plug SAS/SATA hard drive bays |
5. |
One GbE LAN ports for NIC 1 (RJ-45) |
6. |
Optional DVD-RW or DVD-ROM drive |
6. |
Optional LO100i 10/100 Mbps LAN port for
IPMI management (RJ-45) |
7. |
Standard 1st and 2nd 3.5"
Non-Hot plug SATA or hot plug SAS/SATA hard drive bays (Small Form Factor
drive cage not shown here. See the Storage Section for orientation of eight
small form factor drive option) |
7. |
Low-Profile slot cover (not used in this
model) |
8. |
Full-height PCI-Express x16 |
9. |
UID - Rear Unit Identification LED |
10. |
One GbE LAN ports for NIC 2 (RJ-45) |
8. |
Eighteen DIMM slots : DDR3 Registered (RDIMM)
or Unbuffered (UDIMM) memory |
|
9. |
Expansion Slots:
Non-Hot Plug Models - One full-length/full height x16 PCI-Express Gen2 slot
Hot Plug Models - One available half-length/full height x16 PCI-Express
Gen2 slot and one internal only PCI-Express Gen2 slot (for internal storage
controller) |
10. |
Quad-Core Intel® Xeon® 5500 series
processors (supports up to two) |
11. |
Power supply (500 Watts - standard, other
PS options available) |
|
At A Glance |
The HP ProLiant DL160 G6 server is a high performance, low cost, ultra-dense,
dual processor capable, 1U rack server for memory intense High Performance
Computing (HPC) environments, Web 2.0, hosting, and general large memory
footprint server deployments.
- Processors:
- Supports up to two Intel® Quad-Core 5500 sequence processors
- Quad-Core Intel® Xeon® processors 5500 sequence with
8 MB Level 3 cache
- Intel® 5520 Chipset
- Memory:
- Up to 144GB, using PC3-10600 or PC3-8500R DDR3 Registered (RDIMM)
memory, operating at 800MHz when fully populated at 3 DIMMs per Channel
in 18 slots.
- Up to 24GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating
at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slots.
- Internal Drive Support:
- Support for up to four 3.5" Non-Hot plug serial ATA (SATA)
hard drives or;
- Support for up to four 3.5" Hot plug Serial Attached SCSI (SAS)
or SATA hard drives.
NOTE: Installation of the Hot
Plug Backplane 1U 2S Kit (512181-B21) is required if ordering third
or fourth Hard Drives for Hot Plug models only.
- Support for 2.5" Hot Plug Serial Attached SCSI (SAS) or SATA
hard drives.
NOTE: Installation of the HP
8SFF Hard Drive Cage & Backplane G6,FIO (515938-B21) is required
if ordering 2.5" Hot Plug hard drives.
- Internal storage capacity of up to 4.0TB (4 x 1TB Hot Plug 3.5"
SATA/SAS), 3.0TB (4 x 750GB Non-Hot Plug SATA) or 2.4TB (8 x 300GB
Hot Plug 2.5" SATA/SAS)
- Network Controller:
- HP NC362i Integrated Dual Port Gigabit Server Adapter
- Storage Controllers:
- Non-Hot Plug SATA Models: HP Embedded SATA RAID Controller (RAID
0, 1, 10)
NOTE: Transfer rate: up to
3 Gb/s SATA
NOTE: To enable RAID on Embedded SATA, use the HP Smart Array
B110i SATA Raid controller, To enable use of the B110i, enter the
ROM based setup utility(RBSU). The option for enabling RAID can be
found in the Advanced section of the RBSU
- Hot Plug SAS/SATA Models: HP P410 Smart Array Controller RAID 0,1,10,
5
NOTE: Transfer rate: up to
3Gb/s
- Expansion Slots:
- Non-Hot Plug Models: Up to two available PCI Express 2.0 slots:
- Slot 1: full-length/full-height PCI-Express 2.0 x16 or
- Slot 1: half-length/full-height PCI-Express 2.0 x16
- Slot 2: low-profile internal only PCI-Express 2.0 x4
- Hot Plug Models: One available PCI-Express slot:
- Slot 1: half-length/full-height PCI-Express 2.0 x16
- Slot 2: low-profile internal only PCI-Express 2.0 x4 - slot
populated by the SAS/SATA storage controller
- Management:
- HP ProLiant Onboard Administrator (powered by the HP Integrated
Lights-Out 100i Baseboard Management Controller) with optional LO100i
Advanced Licenses for Virtual KVM and Virtual Media
- The HP ProLiant Easy Set-up CDs and ISO image downloads offer Assisted
and Manual single server installation, setup, and deployment capability.
Capabilities provided are:
- AutoRun
- Assisted Installation Microsoft Windows 2003 Server and Microsoft
Windows 2008 Server.
- OS and SW available for Manual Installation are listed on each
servers' QuickSpecs
- HP Insight Diagnostics
- Smart Components - a self-executable software consisting of driver
and firmware
- HP Smart Update Manager - a single system and multi-server deployment
tool for Windows environments that works with Smart Components to
provide customers with easy-to-use GUI and Script-based deployment
capacity
- SmartStart Scripting Toolkit - an automated scalable deployment
utility
- Enhanced HP ProLiant 100 series environmental monitoring that is
similar and consistent to that of HP ProLiant 300 series servers and
above. This server now offers the HP Insight Management Agents and
HP Insight Management WBEM Providers, two well established sets of
management and Internet standards technologies that provide capabilities
which provide integration to HP Systems Insight Manager (SIM).
- Array Configuration Utility (ACU)
- Array Diagnostics Utility (ADU)
- Ports:
- Five USB ports (two front, one internal, two rear)
NOTE: In order to utilize the
internal USB port the USB cable (P/N: 536769-B21) must be connected
to the internal USB header.
- Optical Drive:
- Support for one (optional): DVD-ROM, DVD RW
- Power Supply:
- 500W Power Supply (Non-Hot Plug, Autoswitching)
- Optional FIO high-efficiency pluggable power supplies: 460W Power
Supply or 750W Power Supply
- Additional Features:
- Support for NVIDIA Quadro FX3700 512MB PCIe x 16 graphics card
NOTE: For more information
on the latest visualization and acceleration qualification status,
please see http://www.hp.com/go/accelerators
- Form Factor:
- Operating Systems:
- Supports Windows, RHEL, SLES, Solaris, VMware, and Citrix Essentials
for XenServer (Retail)
- Deployment/Serviceability:
- HP ProLiant DL160 G6 models have fixed rails which provide support
for racks with round mounting holes and tool-free support for racks
with square mounting holes (including Compaq/HP 7000, 9000, 10000
and HP series), with an adjustment range of 26" - 36"
- Tool-less access to all system components for easy in rack serviceability
- Customer Self Repair (CSR): HP products are designed with many CSR
parts to minimize repair time and allow for greater flexibility in
performing defective parts replacement
- Warranty:
- This product is covered by a global limited warranty and supported
by HP Services and a worldwide network of HP Authorized Channel Partners.
Hardware diagnostic support and parts replacement is available for
three years from date of purchase. Support for software and initial
setup is available for 90 days from date of purchase. Enhancements
to warranty services are available through HP Care Pack services or
customized service agreements. SATA hard drives have a one year warranty.
SAS Midline drives have a one-year warranty. SAS Enterprise drives
have a three-year warranty.
NOTE: Server Warranty includes
3 year Next Day Parts replacement, 0-Years Labor, 0-Years Onsite support.
Additional information regarding worldwide limited warranty and technical
support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html.
|
Standard Features
Processor
One of the following depending on Model |
Intel® Xeon® Processor
X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3)
NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details. |
Intel® Xeon® Processor
X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
Intel® Xeon® Processor
E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2)
NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details. |
Intel® Xeon® Processor
E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
Intel® Xeon® Processor
L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) |
Intel® Xeon® Processor
E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) |
NOTE: HT indicates
that the processor model supports Intel® Hyper-Threading Technology.
NOTE: Turbo indicates the maximum potential frequency increment when
using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual
memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5500 Series, the letter preceding the model number
indicates the performance/wattage of the processor. "X" denotes
High Performance/Wattage; "E" denotes Enterprise Performance/Wattage
(Mainstream); and "L" denotes Lower Wattage. |
|
Upgradeability |
Upgradeable to two processors |
|
Chipset |
Intel® 5520 Chipset |
|
Cache Memory |
4 MB Level 3 cache (E5504) |
8 MB Level 3 cache (standard) |
|
Memory Protection |
Advanced memory protection |
|
Memory |
Type |
DDR3 Registered
(RDIMM) or Unbuffered (UDIMM) |
Standard |
4 GB |
(2 x 2 GB) UDIMMs |
6 GB |
(3 x 2 GB) UDIMMs |
12 GB |
(6 x 2 GB) RDIMMs |
Maximum (RDIMM) |
144 GB |
(18 x 8 GB) |
Maximum (UDIMM) |
24 GB |
(12 x 2 GB) |
NOTE: Depending
on the memory configuration and processor model, the memory speed may run
at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration
Tool at: www.hp.com/go/ddr3memory-configurator. |
DDR3
memory options part number decoder
 |
|
Network Controller |
HP NC362i Integrated Dual Port
Gigabit Server Adapter |
|
Expansion Slots # |
Technology
|
Bus Width
|
Connector Width*
|
Bus Number*
|
Device No.**
|
Form Factor
|
Notes
|
1 |
PCI-Express 2.0
|
x16
|
x16
|
1
|
0
|
Full length, full height
|
3.3 volts
|
2*** |
PCI-Express 2.0 |
x4 |
x4 |
6 |
3 |
Low Profile, Internal
Only |
3.3 volts |
|
NOTE:
All slots can accept universal keyed PCI cards |
* Default
bus assignment. Inserting cards with PCI bridges may alter the actual bus
assignment number. |
** Slots
are enumerated differently based on OS. MS OS's enumerate from lowest to
highest Device ID by bus (starting with the lowest bus). |
***In order
to access expansion slot #2, the low profile internal only slot, expansion
slot #1 may only be populated with a half length, full height form factor
card. |
|
Storage Controller |
Non-Hot Plug SATA
Models |
HP Embedded SATA RAID Controller
(integrated into the south-bridge) supporting SW RAID 0,1,10
NOTE: Transfer rate: up to 3 Gb/s
SATA |
HP Smart Array B110i SATA RAID
NOTE: To enable RAID for embedded
SATA controller, use EZ set-up CD to download driver, hpahcisr.sys, is part
of the 8.20 PSP, Smart Start, EZSetup CD. For more information on SW Smart
Array, go to: http://www.HP.com/go/SWRAID |
Hot Plug SATA/SAS Models |
HP Smart Array P410 RAID Controller
(RAID 0/1/1+0/5/5+0)
NOTE: Transfer rate: up to 3 Gb/s
SATA, up to 3 Gb/s SAS. |
NOTE:
A diskette drive or virtual FDD using LO100 Advanced Pack is needed to install
storage controller drivers during a Windows operating system installation
from a CD.
NOTE: RAID 6 functionality requires the addition of Smart Array Advanced
Pack (P/N: 516471-B21). |
|
Storage |
Optical Drives: |
|
DVD-ROM |
SATA 9.5mm DVD-ROM drive, slim
(optional) |
DVD RW |
SATA 9.5mm DVD RW drive (optional) |
Diskette Drives |
Via USB only |
Drive Bays: |
|
Non-Hot Plug SATA |
Up to 4 Non-hot plug SATA 3.5"
drives |
Hot Plug SATA/SAS |
Up to 4 Hot plug SAS/SATA 3.5"
drives |
|
Maximum Internal
Storage |
Non-Hot Plug SATA |
3.0TB |
4 x 750GB |
Hot Plug SATA |
4.0TB |
4 x 1TB |
Hot Plug SAS |
4.0TB |
4 x 1TB |
|
Interfaces |
Parallel |
None |
Network RJ-45(Ethernet) |
2 10/100/1000 NIC ports (plus
1 optional dedicated port for the HP ProLiant Lights Out 100i Remote Management) |
Serial |
1 |
Pointing Device (Mouse) |
0 (via USB only) |
Graphics |
1 |
Keyboard |
0 (via USB only) |
USB |
5 (two front, one internal,
two rear)
NOTE: In order to connect a USB device
internally, the internal USB Cable G6 Kit must be used (536769-B21)
NOTE: Please see the following URL for additional information regarding
USB support:
http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
Graphics |
32MB shared supporting 1600x1200x16M resolution
|
|
Form Factor |
Rack (1U), (1.75 in/4.45 cm) |
|
Embedded Systems Management |
HP ProLiant Onboard Administrator and LO100i Advanced
|
HP ProLiant Onboard Administrator (powered by LO100i Lights-Out 100 Baseboard
Management Controller) with Optional LO100i Advanced Licenses for Virtual
KVM and Virtual Media.
Features:
- Embedded IPMI standard reporting
- System event log access
- Remote Serial console (serial redirection)
- Browser, Telnet access
- SMASH-CLP compliant
- IPMI 2.0 compliant
- Secure Socket Layer Encryption
- Secure Shell Encryption
- Virtual media (Floppy, CD, USB 2.0) with Advanced License
Virtual KVM with Advanced License
|
Server Management
Stand Alone Software Products |
HP Insight Rapid Deployment
software |
HP Insight Rapid Deployment
software (RDP) extends HP Systems Insight Manager with a complete deployment
solution for HP ProLiant servers. RDP provides a central location to configure
server hardware, deploy Windows, Linux and VMware ESX operating environments
and install using images and scripted profiles. For more information, visit:
http://www.hp.com/go/rdp.
NOTE: Flexible and volume quantity
license kits are available for Insight Software products. Refer to: http://www.hp.com/servers/proliantessentials
or the various Insight Software product QuickSpecs for more information. |
HP Systems Insight Manager |
HP Systems Insight Manager (HP
SIM) provides a unified, secure and extensible standards-based environment
to centrally manage servers, storage and other infrastructure devices, (both
HP and non-HP) across multiple operating system platforms.
NOTE: With the G6 platform, HP Insight
Management Agents and Insight Management Providers are available for complete
Systems Insight Manager (SIM) Integration. |
|
Core Infrastructure Management |
Subscriber's Choice |
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based
email subscription service that provides software and driver change notifications
for ProLiant products. Sign up at: http://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis.
|
ROMPaq, software and latest drivers |
The latest software, drivers, and firmware fully optimized and tested
for your ProLiant server and options; downloaded from Software and Drivers
download pages website at: http://www.hp.com/go/support
and from www.hp.com/servers/easysetup.
Contains the following:
- HP Insight Management Agents and Insight Management Providers for
Systems Insight Manager (SIM) Integration
- HP Systems Management Homepage
- Array Configuration Utility (ACU)
- Array Diagnostics Utility (ADU)
- HP Insight Diagnostics
|
|
HP Serviceguard for Linux (SG/LX) |
HP Serviceguard for Linux is a high availability clustering solution
designed to protect applications and services from a wide variety of software
and hardware failures, monitoring the health of each server (node) and
quickly responding to failures such as those that affect system processes,
system memory, LAN media and adapters, and application processes.
The following is a quick summary of HP Serviceguard for Linux features
and support. For the most recent list of Linux distributions & kernels,
servers and storage supported with Serviceguard for Linux, see the Serviceguard
for Linux Datasheet, available at: http://www.hp.com/go/sglx/info.
- Supported Linux Distributions:
- Red Hat EL 4
- Red Hat EL 5
- SUSE SLES10
- Supported Server Platforms
- HP Integrity BladeSystem to Superdome
- HP ProLiant BladeSystem p-Class & c-Class
- HP ProLiant DL
- HP ProLiant ML
- IBM System x
- Dell PowerEdge
- Sun x64
- Fujitsu Siemens PRIMERGY
- Supported Virtual Machines
- SG/LX in HP Integrity Virtual Machines guests
- SG/LX in VMware ESX guests
- SG/LX in Red Hat and SUSE Xen hosts (DOM0)
- Application Integration Toolkits
- HP Serviceguard for Linux Oracle Database Toolkit
- HP Serviceguard Extension for SAP on Linux (SGeSAP/LX)
- Free Application Integration Toolkits:
- Apache
- MySQL
- NFS
- PostgreSQL
- Samba
- Tomcat
- Sendmail
- Disaster Tolerant Solutions
- HP Serviceguard for Linux Extended Distance Cluster (XDC) extends
cluster distances up to 100 km, utilizes software RAID mirroring for
data replication and is storage array independent
- HP StorageWorks XP/EVA Cluster Extension Software for Linux (CLX)
works seamlessly with HP Serviceguard for Linux, HP StorageWorks Continuous
Access, and HP Disk Arrays to automate failover and failback between
sites
- Software updates are distributed by HP Services to customers with
support contracts
NOTE: For additional information on
HP Serviceguard for Linux, visit: http://www.hp.com/go/sglx
or see the HP Serviceguard for Linux QuickSpecs.
NOTE: HP Serviceguard for Linux products for HP ProLiant and select
3rd party x86 class servers include one year of 24 x 7 HP Software Technical
Support and Update Service ensuring rapid access to HP support staff and
proactive delivery of software updates. For more information about this
service, please visit: http://www.hp.com/services/swsupport.
|
|
Industry Standard
Compliance |
ACPI V2.0 Compliant |
PCI 2.2 Compliant |
PXE Support |
WOL Support |
Microsoft® Logo certifications |
IPMI 2.0, SMASH CLP compliant |
|
Security |
Power-on password
Setup password
Diskette boot control
Secure Sockets Layer (SSL)
Secure Shell (SSH) |
Security - Trusted Platform
Module |
The TPM (Trusted Platform Module)
is a microcontroller chip that can securely store artifacts used to authenticate
the server platform. These artifacts can include passwords, certificates
and encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker)
is a data protection feature available in Windows Server® 2008. BitLocker
leverages the enhanced security capabilities of a Trusted Platform Module
(TPM) version 1.2. The TPM works with BitLocker to help protect user data
and to ensure that a server running Windows Server 2008 has not been tampered
with while the system was offline.
NOTE: For more information about
TPM, including a white paper, go to: http://www.hp.com/go/TPM
NOTE: ProLiant OS pre-installed units will come with the partition
required for TPM deployment.
NOTE: The TPM key is unique to every TPM deployed server and must
be retained. Misplacing or losing the key could result in data loss. |
|
Server Power Cords |
One 6' Highline (IEC-IEC) power
cord ships standard
NOTE: HP ProLiant DL servers no longer
ship standard with NEMA power cords (163719-002) that allow connection to
110V US wall outlets in a home or office. ProLiant DL servers are primarily
connected to PDU's in data center racks so they now ship standard with only
a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server
using a 110V receptacle (NEMA-15), the NEMA power cord (227099-001) must
be ordered separately.
If customers require a local power cord, they can check the power cord matrix
for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix. |
|
Power Supply |
500 Watts, auto-switching, high
efficiency, PFC (Power Factor Correcting) |
NOTE: Factory
upgradeable to high-efficiency (HE) pluggable power supply |
|
System Fans |
6 system fans ship standard;
Non-hot plug, Non-redundant |
|
Rack Airflow Requirements |
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack
is used, observe the following additional requirements to ensure adequate
airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and
rear doors, you must allow 5,350 sq cm (830 square inches) of hole evenly
distributed from top to bottom to permit adequate airflow (equivalent
to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side
panels of the rack must be a minimum of 7 cm (2.75 inches)
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
|
NOTE: For additional
information, refer to the Setup and Installation Guide or the Documentation
CD provided with the server, or to the server documentation located in the
Support section at the following URL: www.hp.com/servers/dl160. |
|
Rack Support |
The DL Fixed Rail System supports installation in racks with square or
round mounting holes (including Compaq/HP 7000, 9000, 10000 and HP series),
with an adjustment range of 24" - 36". Installation into Telco
2 post, and 4 post, or threaded holes racks requires a 3rd party option
kit. For additional information, please visit: www.racksolutions.com.
|
|
Factory Express Portfolio for
Servers and Storage |
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed.
Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging, and custom packaging.
HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades,
HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP,
rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server
model please contact your sales representative or go to: http://www.hp.com/go/factory-express.
| |
HP Enterprise Configurator |
The HP eConfigure Enterprise
Configurator now provides factory default racking for our HP hardware portfolio.
This approach is aligned with our strategic direction to meet the needs
and expectations of our valued customers. If you require "custom"
rack configuration, please contact HP's Customer Business Center or an Authorized
Partner for assistance. |
|
Service and Support |
HP Care Pack Services provide total care and support expertise with
committed response designed to meet your IT and business needs.
HP Care Pack Services provide total care and support expertise with committed
response designed to meet your IT and business needs.
HP Care Pack services include coverage for the HP branded hardware options
qualified for the server that are purchased at the same time or afterward
and internal to the enclosure. It also includes the 22" and smaller
external monitors and tower UPS options up to 3kVA. These items will be
covered at the same service level and for the same coverage period as
the server. Coverage of UPS Battery is not included and standard warranty
terms & conditions apply. For servers or storage systems installed
within a rack, service also covers all HP qualified rack options installed
within the same rack.
To fully capitalize on your HP ProLiant servers' capabilities requires
a service partner who thoroughly understands your server technology and
systems environment. HP Services, an industry leader in provision of multi
vender support solutions provides a range of support services designed
to meet the varying needs of business. Whether an SMB or large global
corporation HP has a ProLiant server support offer to help you speedily
deploy and maximize system uptime.
Recommended Service - Simplify ProLiant solution implementation,
maintenance and management.
- Support Service - 3 Year, 9x5 Next Business Day coverage, excluding
HP holidays only
- Deployment Service - Hardware Installation only
Enhanced Service - Optimize service level to increase IT performance
and availability
- Support Service - 3 Year 13x5 Same Business Day, 4-Hour response
coverage
- Deployment Service - Installation and Start-up only
Installation & Start-Up of a ProLiant server and Microsoft or Linux
O/S per the Customer Description and/or Data Sheet. To be delivered on
a scheduled basis 8am-5pm, M-F, excl. HP holidays.
For a complete listing of service offerings and information visit:
http://www.hp.com/services/proliantservices
http://www.hp.com/go/proliant/carepack
|
HPC Interconnects
NOTE:
High Performance Computing (HPC) interconnect technologies are available
for the DL160 G6 under the Cluster Platform product portfolio. These high-speed
interconnects are fully supported by HP when they are part of these configure
to order clusters. Solutions can be defined with a lot of flexibility with
the help of configuration tools. Please visit the following URL to configure
HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects:
http://www.hp.com/techservers/clusters/ucp/index.html |
|
HPC Interconnects |
InfiniBand |
PCI-Express Generation 2 adapters |
Gigabit Ethernet |
Use embedded ports |
10-Gigabit Ethernet |
PCI-Express Generation 2 |
Models
Non-Hot Plug Serial ATA (SATA)
Models
NOTE: Non-Hot Plug models are not
upgradeable to Hot Plug.
|
HP DL160G6 E5504 NHP SATA, 4GB
490427-xx1
HP DL160G6 L5520 NHP SATA, 4GB
490432-xx1
|
Processor(s)
One of the following depending on model |
Intel® Xeon® Processor
E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)
Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066,
HT, Turbo 1/1/2/2) |
Cache Memory |
4MB shared L3 cache (E5504) |
8MB shared L3 cache (L5520) |
Memory |
4GB (2 x 2GB) PC3-10600E (UDIMM) |
Network Controller |
HP NC362i Integrated Dual Port
Gigabit Server Adapter |
Storage Controller |
Embedded SATA RAID 0, 1, 10 |
Hard Drive |
HP 160GB 7.2k Non Hot Plug SATA |
Internal Storage |
Up to 4 large form factor Non-Hot
Plug drives |
Optical Drive |
None ships standard |
Power Supply |
500W high efficiency multi-output
supply (ships standard) |
Form Factor |
1U |
|
Hot Plug Serial ATA (SATA)/ Serial Attached SCSI (SAS)
Models
NOTE: Up to 4 large form factor
hard drives supported in server model (P/N 490455-B21).
NOTE: Up to 2 large form factor hard drives supported in server
models (P/N 490454-B21 and 490442-B21).
|
HP DL160G6 E5504 Hot Plug,4GB
490442-xx1
HP DL160G6 E5520 Hot Plug, 6GB
490454-xx1
HP DL160G6 X5550 Hot Plug, 4LFF, 12GB
490455-xx1
|
Processor(s)
One of the following depending on model |
Intel® Xeon® Processor
E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800)
Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2)
Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333,
HT, Turbo 2/2/3/3) |
Cache Memory
One of the following depending on model |
4MB shared L3 cache (E5504) |
8MB shared L3 cache |
Memory
One of the following depending on model |
4GB (2 x 2GB) PC3-10600E (UDIMM) |
6GB (3 x 2GB) PC3-10600E (UDIMM) |
12GB (6 x 2GB) PC3-10600R (RDIMM) |
Network Controller |
HP NC362i Integrated Dual Port
Gigabit Server Adapter |
Storage Controller |
P410 Smart Array SAS/SATA RAID
0,1,10, 5 |
Hard Drive |
None ship standard |
Internal Storage
One of the following depending on model |
Up to 4 large form factor Hot
Plug drives |
Up to 2 large form factor Hot
Plug drives |
Optical Drive |
None ship standard |
Power Supply |
500W high efficiency multi-output
supply (ships standard) |
Form Factor |
1U |
|
Country Code Key |
xx = 00 |
U.S. |
xx = 20 |
Brazil (ONLY P/N 490442-xx1) |
xx = 29 |
Japan |
xx = 37 |
APD |
xx = 42 |
Euro |
xx = AA |
PRC |
Configuration Information - Factory Integrated Models
NOTE: This section lists some of the steps required to configure
a Factory Integrated Model. To ensure only valid configurations are ordered,
HP recommends the use of an HP approved configurator. Contact your local
sales representative for additional information.
NOTE: HP does not allow factory integration of options into standard
models listed above. Configure-to-order servers must start with a CTO
Chassis.
NOTE: FIO indicates that this option is a Factory Installable Option.
|
Step
1: Base Configuration (choose one of the following configurable models) |
|
Non-Hot Plug SATA
Model
NOTE: Non-Hot Plug models are not
upgradeable to Hot Plug. |
|
HP ProLiant DL160
G6 Non-Hot Plug SATA Rack CTO Chassis |
491531-B21 |
Factory Integrated
Model ships with: |
|
HP NC362i Integrated
Dual Port Gigabit Server Adapter |
|
One available full-length/full-height
PCI-Express x16 Generation 2 slot |
|
One Highline IEC
Power Cord |
|
6 Non-Hot Plug Fans |
|
Rack (1U), (1.75
in / 4.45 cm) |
|
Tool-less Fixed Rails |
|
Hot Plug Model |
|
HP ProLiant DL160
G6 Hot Plug SAS/SATA Rack CTO Chassis |
491532-B21 |
Factory Integrated
Model ships with: |
|
HP NC362i Integrated
Dual Port Gigabit Server Adapter |
|
One available PCI-Express
Generation 2 slot:
Slot 1: half-length/full-height
Slot 2: low-profile/half-height - occupied by controller card |
|
One Highline IEC
Power Cord |
|
6 Non-Hot Plug Fans |
|
Rack (1U), (1.75
in / 4.45 cm) |
|
Tool-less Fixed Rails |
|
|
Step
2: Choose Required Options (only one of the following from each list unless
otherwise noted) |
Processors |
Quad-Core Processors |
|
Intel® Xeon®
Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3),
FIO
NOTE: If 2 processors are desired,
select one 508231-L21 and one 508231-B21. |
508231-L21 |
Intel® Xeon®
Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3),
FIO
NOTE: If 2 processors are desired,
select one 491511-L21 and one 491511-B21. |
491511-L21
|
Intel® Xeon®
Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2),
FIO
NOTE: If 2 processors are desired,
select one 490461-L21 and one 490461-B21. |
490461-L21
|
Intel® Xeon®
Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2),
FIO
NOTE: If 2 processors are desired,
select one 490459-L21 and one 490459-B21. |
490459-L21
|
Intel® Xeon®
Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2),
FIO
NOTE: If 2 processors are desired,
select one 491507-L21 and one 491507-B21. |
491507-L21
|
Intel® Xeon®
Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO
NOTE: If 2 processors are desired,
select one 490457-L21 and one 490457-B21. |
490457-L21
|
NOTE:
HT indicates that the processor model supports Intel® Hyper-Threading
Technology.
NOTE: Turbo indicates the maximum potential frequency increment when
using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual
memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5500 Series, the letter preceding the model number
indicates the performance/wattage of the processor. "X" denotes
High Performance/Wattage; "E" denotes Enterprise Performance/Wattage
(Mainstream); and "L" denotes Lower Wattage. |
|
|
Memory |
Registered DIMMs
(RDIMMs) |
|
HP 2GB 2Rx8 PC3-10600R-9
Kit |
500656-B21 |
HP 4GB 2Rx4 PC3-10600R-9
Kit |
500658-B21
|
HP 4GB 4Rx8 PC3-8500R-7
LP Kit |
500660-B21
|
HP 8GB 2Rx4 PC3-10600R-9
Kit |
500662-B21 |
HP 8GB 2Rx4 PC3-8500R-7
Kit |
516423-B21
|
Unbuffered with ECC
DIMMs (UDIMMs) |
|
HP 1GB 1Rx8 PC3-10600E-9
Kit |
500668-B21 |
HP 2GB 2Rx8 PC3-10600E-9
Kit |
500670-B21 |
NOTE:
All DDR3 memory option kits consist of one DIMM per kit. For detailed memory
configuration rules and guidelines, please use the Online DDR3 Memory Configuration
Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information
on ProLiant Energy Efficient Features, see: http://www.hp.com/go/proliant-energy-efficient |
|
NOTE:
There is a maximum support limitation of 8 ranks per memory channel (maximum
of 2 quad rank DIMMs per channel) |
|
|
Hard
Drive |
NOTE:
Transfer rates of drives are dependent on the maximum transfer rate supported
by the Controller. Refer to the Controller technical specifications for
details. |
|
SATA Non-Hot Plug
Midline (MDL) Drive
NOTE: A minimum of one hard drive
is required when purchasing Non-Hot Plug CTO Chassis Model (P/N 491531-B21).
NOTE: SATA Non-Hot Plug Hard Drives ONLY required when purchasing
Non-Hot Plug CTO Chassis Models (491531-B21) in Step 1. |
|
HP 750GB 3G SATA
7.2K NHP 3.5" MDL HDD |
462595-B21
|
HP 500GB 3G SATA
7.2K NHP 3.5" MDL HDD |
458941-B21
|
HP 250GB 3G SATA
7.2K NHP 3.5" MDL HDD |
458939-B21
|
SATA Non-Hot Plug
Entry (ETY) Drives |
|
HP 160GB 3G SATA
7.2K NHP 3.5" ETY HDD |
458947-B21 |
|
Storage
Controllers |
NOTE:
A minimum of one Smart Array Controller is required when purchasing Hot
Plug CTO Chassis Model (P/N 491532-B21).
NOTE: The below storage controllers are intended for use with internal
drives in the Hot Plug CTO Chassis Model ONLY (P/N 491532-B21). |
|
NOTE:
In order to upgrade to RAID 6, at least 256MB Cache and a Battery is required
in addition to the Smart Array Advanced Pack license (516471-B21).
NOTE: When selecting the P212 (491191-B21), the controller will be
installed in the x16 slot since it has both an internal and external port.
This prevents the use of the internal slot and no PCI-E slots will be available. |
|
HP P212/256 MB FIO
Smart Array BBWC |
491191-B21
|
HP P410/ZM FIO Smart
Array Controller |
462860-B21
|
|
Hot Plug HDD Backplane
Option |
HP 8SFF Hard Drive
Cage & Backplane G6, FIO |
515938-B21
|
|
Power
Supply |
Many HP
ProLiant Servers now offer new power options, including Common Slot Power
Supplies. These power supplies come in multiple power ratings and higher
efficiency levels to offer the Right Size solution to fit your configuration.
This provides improved power delivery and the advantage of reclaiming lost
power. Prior to making a power supply selection it is "highly recommended"
that the "HP Power Advisor" is run to determine the right size
power supply for your server configuration. The HP Power Advisor is located
at: www.hp.com/go/proliant-energy-efficient |
|
HP High Efficiency
500W Multi-output Power Supply Kit |
515915-B21
|
HP High Efficiency
460W Power Supply Kit |
535684-B21
|
HP High Efficiency
750W Power Supply Kit |
535683-B21 |
|
Step 3: Choose
Additional Options for Factory Integration |
NOTE:
For additional "Core Options" and "Additional Options",
please refer to the "Options" section below. Some options may
not be available for factory integration. Please contact an HP sales representative
for additional information. |
Core Options
Processor |
Quad-Core Processors |
|
Intel® Xeon® Processor
E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
490461-B21 |
Intel® Xeon® Processor
E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
490459-B21 |
Intel® Xeon® Processor
E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) |
490457-B21 |
Intel® Xeon® Processor
L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) |
491507-B21 |
Intel® Xeon® Processor
X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
508231-B21 |
Intel® Xeon® Processor
X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
491511-B21 |
NOTE: HT indicates
that the processor model supports Intel® Hyper-Threading Technology.
NOTE: Turbo indicates the maximum potential frequency increment when
using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual
memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5500 Series, the letter preceding the model number
indicates the performance/wattage of the processor. "X" denotes
High Performance/Wattage; "E" denotes Enterprise Performance/Wattage
(Mainstream); and "L" denotes Lower Wattage. |
|
|
Memory
|
Registered DIMMs (RDIMMs) |
|
HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21
|
HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
HP 4GB 4Rx8 PC3-8500R-7 LP Kit |
500660-B21
|
HP 8GB 2Rx4 PC3-10600R-9 Kit |
500662-B21 |
HP 8GB 2Rx4 PC3-8500R-7 Kit |
516423-B21
|
Unbuffered with ECC DIMMs (UDIMMs) |
|
HP 1GB 1Rx8 PC3-10600E-9 Kit |
500668-B21 |
HP 2GB 2Rx8 PC3-10600E-9 Kit |
500670-B21 |
NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information
on ProLiant Energy Efficient Features, see: http://www.hp.com/go/proliant-energy-efficient |
|
|
Optical Drives
|
DVD-ROM Drive (optional) |
481045-B21
|
DVD RW Drive (optional) |
481047-B21 |
|
Hard Drives |
NOTE: Transfer
rates of drives are dependent on the maximum transfer rate supported by
the HBA or Controller. Refer to the HBA or Controller technical specifications
for details. |
|
SATA Non-Hot Plug Midline (MDL)
Drives (Non-Hot Plug Models Only) |
|
HP 750GB 3G SATA 7.2K
NHP 3.5" MDL HDD |
462595-B21
|
HP 500GB 3G SATA 7.2K NHP 3.5"
MDL HDD |
458941-B21
|
HP 250GB 3G SATA 7.2K NHP 3.5"
MDL HDD |
458939-B21
|
SATA Non-Hot Plug Entry (ETY)
Drives |
|
HP 160GB 3G SATA 7.2K NHP 3.5"
ETY HDD |
458947-B21
|
SATA Hot Plug Midline (MDL)
Drives (SAS/SATA Hot Plug Models Only)
NOTE: A SAS HBA or Array Controller
is required. |
|
HP 1TB 3G SATA 7.2K 3.5"
MDL HDD |
454146-B21
|
HP 750GB 3G SATA 7.2K 3.5"
MDL HDD |
458930-B21
|
HP 500GB 3G SATA 7.2K 3.5"
MDL HDD |
458928-B21 |
HP 250GB 3G SATA 7.2K 3.5"
MDL HDD |
458926-B21 |
SATA Hot Plug Entry (ETY) Drives |
|
HP 160GB 3G SATA 7.2K 3.5"
ETY HDD |
458945-B21 |
HP 250GB 3G SATA 5.4K SFF ETY
HDD |
460355-B21 |
HP 120GB 1.5G SATA 5.4K SFF ETY
HDD |
458924-B21 |
NOTE: SATA hard
drives have a 1-year warranty. Please see QuickSpecs for Technical Specifications
and additional information:
http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html
(Worldwide) |
|
SAS Hot Plug 3.5" Midline
(MDL) Drives |
|
HP 1TB 7.2K 3.5" DP SAS MDL
HDD |
461137-B21 |
HP 750GB 7.2K 3.5" DP SAS
MDL HDD |
461135-B21
|
SAS Hot Plug Enterprise (ENT)
Drives |
|
HP 300GB 6G SAS 10K SFF DP ENT
HDD |
507127-B21 |
HP 300GB 3G SAS 10K SFF DP ENT
HDD |
492620-B21 |
HP 146GB 6G SAS 10K SFF DP ENT
HDD |
507125-B21 |
HP 146GB 3G SAS 10K SFF DP ENT
HDD |
418367-B21 |
HP 146GB 3G SAS 15K SFF DP ENT
HDD |
504062-B21 |
HP 72GB 3G SAS 15K SFF DP ENT
HDD |
418371-B21 |
HP 72GB 3G SAS 10K SFF DP ENT
HDD |
384842-B21 |
HP 36GB 3G SAS 15K SFF DP ENT
HDD |
418369-B21 |
SAS Hot Plug 3.5" Enterprise
(ENT) Drives |
|
HP 450GB 3G SAS 15K 3.5"
DP ENT HDD |
454232-B21 |
HP 400GB 3G SAS 10K 3.5"
DP ENT HDD |
459508-B21 |
HP 300GB 3G SAS 15K 3.5"
DP ENT HDD |
416127-B21 |
HP 146GB 3G SAS 15K 3.5"
DP ENT HDD |
384854-B21 |
HP 72GB 3G SAS 15K 3.5" DP
ENT HDD |
384852-B21 |
NOTE: The purchase
of SAS HBA or array controller is required. |
|
NOTE: SAS Enterprise
drives have a 3-year warranty Please see the QuickSpecs for Technical Specifications
and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html
(Worldwide) |
|
|
Communications |
HP NC112T PCIe Gigabit Server
Adapter |
503746-B21
|
HP NC360T PCI Express Dual Port
Gigabit Server Adapter |
412648-B21
|
HP NC373F PCI Express Multifunction
Gigabit Server Adapter |
394793-B21
|
HP NC373T PCI Express Multifunction
Gigabit Server Adapter |
394791-B21
|
HP NC382T PCI Express Dual Port
Multifunction Gigabit Server Adapter |
458492-B21
|
HP NC364T PCI Express Quad Port
Gigabit Server Adapter |
435508-B21 |
HP NC522SFP Dual Port 10GbE Server
Adapter |
468332-B21
|
NOTE: A minimum
of two Gigabtyes (2GB) of server memory is required for each NC522SFP adapter.
NOTE: Please see the QuickSpecs for Technical Specifications and
additional information: www.hp.com/go/ProLiantNICs |
|
|
Additional Server Options
|
HP Dedicated Management Port
Kit |
516006-B21
|
Additional Options
Remote Management |
HP LO100i Advanced Pack, No Media 1-Server
License including 1 year of 24x7 Technical Support and Updates
NOTE: For additional License Kits
please see the Lights-Out 100i QuickSpecs at: www.hp.com/go/lo100 |
530521-B21 |
|
HP
Insight Control Suite (ICE) |
NOTE: Electronic licensing options are available for Insight Control
suites software products. Please see the appropriate Insight Control QuickSpecs
for additional information. www.hp.com/go/ice
NOTE: As of January 26, 2009, HP Insight Control Environment for BladeSystem
suite is being combined into HP Insight Control Suite (ICE).
- ICE standalone license covers iLO Advanced Pack, SIM, RDP, IPM, PMP,
VPM, VMM
- ICE license purchased with a c-Class enclosure covers iLO Advanced
for BladeSystem, SIM, RDP, IPM, PMP, VPM and VMM
|
|
HP Insight Control suite for Linux |
|
HP Insight Control suite for Linux, Media
pack (DVD) - No licenses included
NOTE: This optional Media pack DVD
contains the ISO image for HP Insight Control Environment for Linux, HP
System Insight Manager, HP Insight Power Manager, HP Insight Virtual Machine
Manager for ProLiant, and an integrated installer. Servers must be acquired
separately.
NOTE: This Media pack is optional because the latest ISO image and
latest updates may be downloaded at no cost from: http://www.hp.com/go/ice-linux
(click on Download button). |
464422-B22 |
HP Insight Control Environment for Linux,
No Media, 1-Server license, including one year of 24x7 Technical Support
and Updates
NOTE: This part number can be used
to purchase one (1) license with a single activation key. Customer will
receive a printed license entitlement certificate via physical shipment.
The license entitlement certificate must be redeemed online or via fax in
order to obtain the license activation key(s). Includes one year of 24 x
7 HP Software Technical Support and Update Service.
NOTE: One certificate is shipped for each license. |
464423-B22 |
NOTE: For additional License
Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_div/13019_div.html |
|
|
Server
Management Stand Alone Software Products |
NOTE: Electronic licensing
options are available for Insight Control suites and select Insight Software
products. Please see the appropriate Insight Control and Insight Software
QuickSpecs for additional information. |
|
Deploy |
|
HP Insight Rapid Deployment software |
|
HP Insight Rapid Deployment software single
license including 1 yr 24x7 Technical Support and Updates
NOTE: This license allows 1 server
to be deployed and managed via RDP. Customer will receive a printed license
entitlement certificate via physical shipment. The license entitlement certificate
must be redeemed online or via fax in order to obtain the license activation
key(s). Includes one year of 24 x 7 HP Software Technical Support and Update
Service. |
452151-B21 |
NOTE: For additional License
Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html |
|
NOTE: Flexible and volume
quantity license kits are available for Insight Software products. Refer
to: http://www.hp.com/servers/proliantessentials
or the various Insight Software product QuickSpecs for more information. |
|
|
Graphic Cards
|
HP NVIDIA FX3700 512 MB PCI-E
16x Kit |
490062-B21
|
|
Hot Plug HDD Backplane Option
|
HP 4HDD Hot Plug Backplane G6
Kit |
512181-B21
|
NOTE: Installation
of the 4 HDD Hot Plug Backplane G6 Kit (512181-B21) is required if ordering
third or fourth Hard Drives for Hot Plug models only. |
|
|
Security
|
HP Trusted Platform Module Option
Kit |
488069-B21
|
|
Storage Controllers |
NOTE: The addition
of storage controllers for internal hard drive use is intended for use ONLY
with the Hot Plug SATA/SAS Model Chassis (P/N 445148-B21).
NOTE: The selection of the HP Smart Array P212 Controller for internal
and external connectivity, will require the use of the Full Length Full
Height PCI-E x16 slot |
|
SAS Controllers |
|
Smart Array P212 Controller |
|
HP P212/ZM Smart Array Controller |
462828-B21
|
HP Smart Array P212/256MB Controller |
462834-B21 |
Smart Array P410 Controller |
|
HP Smart Array P410/256 |
462862-B21
|
HP Smart Array P410/256 MB BBWC |
491195-B21
|
HP Smart Array P410/512 MB BBWC |
462864-B21
|
Storage Controllers for use with
External Storage Only |
|
HP Smart Array P411/256MB Controller |
462830-B21
|
HP Smart Array P411/512MB BBWC |
462832-B21
|
NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13203_div/13203_div.html
(Smart Array P212 Controller)
http://h18000.www1.hp.com/products/quickspecs/13201_div/13201_div.html
(Smart Array P410 Controller)
http://h18000.www1.hp.com/products/quickspecs/13202_div/13202_div.html
(Smart Array P411 Controller) |
|
|
HPC Specific Options |
HP IB 4X DDR Conn-X PCI-e G2 Dual
Port HCA |
483514-B21
|
HP IB 4X DDR PCI-e DUAL PORT HCA |
448397-B21 |
HP IB 4X QDR Conn-X PCI-e G2 Dual
Port HCA |
517721-B21 |
NOTE: For HPC
interconnect adapters please see the HPC Interconnect section of this QuickSpecs. |
|
|
Tape Drives |
NOTE: For the complete listing of Tape Drive offerings, please
see:
http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
|
|
USB Rack-Mount Tape Drives |
|
HP StorageWorks 1U USB Rack-Mount
Kit with one DAT 160 USB Tape Drive
NOTE: Pre-configured with one DAT
160 USB tape drive. |
AG703A
|
SAS Rack-Mount Tape Drives
NOTE: HP recommends purchasing the
HP Smart Array P212 (P/N 464828-B21) for a dedicated SAS HBA for tape. |
|
HP StorageWorks 1U SAS Rack-Mount
Kit with one LTO-4 Ultrium 1760
NOTE: Pre-configured with one LTO-4
Ultrium 1760 SAS tape drive. |
EH946A
|
HP StorageWorks 1U SAS Rack-Mount
Kit
NOTE: Supports up to (2) half-height
SAS tape drives. |
AE459A
|
HP StorageWorks DAT 160 SAS Internal
Tape Drive
NOTE: Mounts inside the 1U SAS Rack-Mount
Kit (AE459A). |
Q1587A
|
HP StorageWorks LTO-2 Ultrium
448 SAS Internal Tape Drive
NOTE: Mounts inside the 1U SAS Rack-Mount
Kit (AE459A). |
DW085A
|
HP StorageWorks LTO-3 Ultrium
920 SAS Internal Tape Drive
NOTE: Mounts inside the 1U SAS Rack-Mount
Kit (AE459A). |
EH847A |
SCSI Rack-Mount Tape Solutions
NOTE: SCSI Controller required. HP
recommends purchasing the HP SC11Xe HBA (412911-B21) for a dedicated SCSI
HBA for tape. |
|
HP StorageWorks 1U SCSI Rack-mount
kit with one LTO-2 Ultrium 448 SCSI Tape Drive (Carbonite)
NOTE: Pre-configured with one LTO-2
Ultrium 448 SCSI tape drive. |
DW028B
|
HP StorageWorks 1U SCSI Rack-mount
kit with one LTO-3 Ultrium 920
NOTE: Pre-configured with one LTO-3
Ultrium 920 SCSI tape drive. |
EH903A
|
HP StorageWorks 3U SCSI Rack-Mount
with 1 LTO-4 Ultrium 1840 Tape Drive
NOTE: Pre-configured with one LTO-4
Ultrium 1840 SCSI tape drive. |
EH926A
|
For an up-to-date listing
of the latest O/S and software support details for HP Ultrium tape drives,
please visit: http://www.hp.com/go/connect |
|
|
Tape Autoloaders |
HP StorageWorks DAT Autoloader |
|
HP StorageWorks DAT 72x10 tape
autoloader |
AE313B |
HP StorageWorks 1/8 G2 Tape Autoloader |
|
HP StorageWorks 1/8 G2 LTO-4 Ultrium
1760 SAS Tape Autoloader |
AK377A |
HP StorageWorks 1/8 G2 LTO-3 Ultrium
920 SAS Autoloader |
AH558A |
HP StorageWorks 1/8 G2 LTO-2 Ultrium
448 Tape Autoloader |
AH164A |
HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit
NOTE: Required to install the 1/8
G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount
instructions. |
AH166A |
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://www.hp.com/go/automation
needed to create a complete solution; reference current compatibility information
at: http://www.hp.com/go/ebs. |
|
|
Tape Libraries
|
HP StorageWorks MSL2024 Tape Library |
|
HP StorageWorks MSL2024 1 LTO-4
Ultrium 1840 SCSI Drive Library |
AJ033A |
HP StorageWorks MSL2024 1 LTO-4
Ultrium 1760 SAS Drive Library |
AK378A |
HP StorageWorks MSL2024 1 LTO-3
Ultrium 960 SCSI Drive Library |
AG115A |
HP StorageWorks MSL2024 1 LTO-3
Ultrium 920 SAS Drive Library |
AH559A |
HP StorageWorks MSL2024 1 LTO-2
Ultrium 448 SCSI Drive Library |
AG116A |
HP StorageWorks MSL4048 Tape Library |
|
HP StorageWorks MSL4048 1 LTO-4
Ultrium 1840 SCSI Drive Library |
AJ035A |
HP StorageWorks MSL4048 2 LTO-4
Ultrium 1760 SAS Drive Library |
AK380A |
HP StorageWorks MSL4048 1 Ultrium
960 SCSI Drive Library |
AG322A |
HP StorageWorks MSL4048 1 Ultrium
920 SAS Drive Library |
AH560A |
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://www.hp.com/go/automation
needed to create a complete solution; reference current compatibility information
at: http://www.hp.com/go/ebs. |
|
|
Disk-Based Backup
|
RDX Removable Disk Backup |
|
HP StorageWorks RDX160 External
Removable Disk Backup System
NOTE: 160GB of Disk Storage. |
AJ766A |
HP StorageWorks RDX320 External
Removable Disk Backup System
NOTE: 320GB of Disk Storage. |
AJ768A |
HP StorageWorks RDX500 External
Removable Disk Backup System
NOTE: 500GB of Disk Storage. |
AJ935A |
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13036_div/13036_div.html |
|
D2D Backup |
|
HP StorageWorks D2D120 Backup
System with Data Protector Express Software Kit
NOTE: 2TB of Disk Storage. |
EH924A |
HP StorageWorks D2D130 Backup
System with LTO-3 Ultrium 920 SAS Tape Drive
NOTE: 3TB of Disk Storage. |
EH952A |
HP StorageWorks D2D2503i Backup
System
NOTE: 3TB of Disk Storage. |
EH945A |
HP StorageWorks D2D4004i Backup
System |
EH938A |
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12651_div/12651_div.html
(Worldwide) |
|
|
High Availability
Cluster Options |
HP Serviceguard for Linux |
|
HP Serviceguard for Linux on HP
ProLiant and other third-party x86 Servers - Physical Media Kit
NOTE: This kit contains media only. |
519353-B21 |
HP Serviceguard for Linux on HP
ProLiant and other third-party x86 Servers Single-Server License
Licensed per Server
NOTE: This license allows Serviceguard
for Linux to be installed on 1 server.
Customer will receive a printed license entitlement certificate via physical
shipment.
The license entitlement certificate must be redeemed online or via fax
in order to obtain the license activation key(s).
Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
519354-B21 |
HP Serviceguard for Linux - Flexible-Quantity
License
(for HP ProLiant and other third-party x86 servers)
Licensed per Server
NOTE: This part number can be used
to purchase multiple licenses with a single
activation key. Customer will receive a printed license entitlement certificate
via
physical shipment. The license entitlement certificate must be redeemed
online or via
fax in order to obtain the license activation key(s).
Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
519355-B21 |
HP Serviceguard Linux Oracle Database
Toolkit for HP ProLiant/x86 Servers
Licensed per cluster
Includes media and One Year 24x7 Software Support & Updates |
463833-B21
|
HP Serviceguard Extension for
SAP on Linux for HP ProLiant/x86 Servers
Licensed per physical server
Includes media and One Year 24x7 Software Support & Updates |
463834-B21
|
HP Serviceguard Linux Extended
Distance Cluster (XDC) for HP ProLiant/x86 Servers
Licensed per physical server
Includes media and One Year 24x7 Software Support & Updates |
463835-B21
|
NOTE: The above
is not a complete list of all HP Serviceguard for Linux product numbers.
For a detailed list of supported configuration/certification options for
HP Serviceguard for Linux, please refer to the HP Serviceguard for Linux
Configuration & Ordering Guide available at: http://www.hp.com/go/sglx/info.
NOTE: HP Serviceguard for Linux products running on x86 platforms
now include one year of 24 x 7 Software Technical Support and Updates. Please
see the Support Information section of the HP Serviceguard for Linux QuickSpecs
for details.
NOTE: For additional information including a complete list of Product
Numbers for HP Serviceguard for Linux, please see the following QuickSpecs
at:
http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html
(Worldwide) |
|
|
StorageWorks Options |
StorageWorks Fibre Channel HBA |
|
NOTE: The following
is a list of all Fibre Channel Host Bus Adapters for Windows and Linux.
For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html |
|
HP StorageWorks FC2142SR 4Gb PCI-e
HBA |
A8002A
|
HP StorageWorks FC1143 4Gb PCI-X
2.0 FC HBA |
AB429A
|
HP StorageWorks FC1243 Dual Channel
4Gb PCI-X 2.0 FC HBA |
AE369A
|
HP StorageWorks FC2143 4Gb PCI-X
2.0 FC HBA |
AD167A
|
HP StorageWorks FC 2243 Dual Channel
4Gb PCI-X 2.0 FC HBA |
AD168A
|
HP StorageWorks 81E 8Gb Single
Port PCI-e FC HBA |
AJ762A |
HP StorageWorks 82E 8Gb Dual Port
PCI-e FC HBA |
AJ763A |
HP StorageWorks 81Q 8Gb Single
Port PCI-e FC HBA |
AK344A |
HP StorageWorks 82Q 8Gb Dual Port
PCI-e FC HBA |
AJ764A |
StorageWorks SCSI HBA |
|
HP U320e SCSI Host Bus Adapter
NOTE: Recommended Dual Channel Ultra320
SCSI Controller for connecting multi-drive MSL tape libraries to ProLiant
servers. |
AH627A
|
|
HP StorageWorks 60 Modular Smart Array
|
HP StorageWorks 60 Modular Smart
Array |
418408-B21
|
NOTE: Rack-mountable
12-drive (3.5" 3G SAS/1.5G SATA) 2U enclosure with 3Gb/s SAS host connectivity
and redundant power supplies.
NOTE: Please see the QuickSpecs for Technical Specifications and
additional information: http://h18000.www1.hp.com/products/quickspecs/12627_div/12627_div.html
(Worldwide) |
|
|
HP StorageWorks 70 Modular Smart Array
|
HP StorageWorks 70 Modular Smart
Array |
418800-B21
|
NOTE: Rack-mountable
25-drive (2.5" 3G SAS/1.5G SATA) 2U enclosure with 3Gb/s SAS host connectivity
and redundant power supplies.
NOTE: Please see the QuickSpecs for Technical Specifications and
additional information: http://h18000.www1.hp.com/products/quickspecs/12652_div/12652_div.html
(Worldwide) |
|
|
Uninterruptible Power Systems - Rack
|
HP UPS R1500 G2 UPS |
|
HP, R1.5k VA UPS, 1U, NA |
AF419A
|
HP, R1.5kVA UPS, 1U, INTL |
AF418A
|
HP, R1.5kVA UPS, 1U, JPN/TW |
AF421A
|
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13130_div/13130_div.html
(Worldwide) |
|
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13129_div/13129_div.html
(Worldwide) |
|
NOTE: For additional
information on HP Uninterruptable Power Systems please go to: www.hp.com/servers/rackups. |
|
HP R3000 UPS |
|
HP R3000 VA UPS, 2U, DTC, INTL |
AF414A |
HP R3000 VA UPS, 2U, Low Voltage
L5-30, NA |
AF422A |
HP R3000 VA UPS, 2U, High Voltage
L6-20, NA |
AF423A |
HP R3000 VA UPS, 2U, High Voltage
L6-20, JPN |
AF424A |
HP R3000 VA UPS, 2U, Low Voltage
L5-30, JPN |
AF425A |
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/10671_div/10671_div.html
(Worldwide) |
|
HP R3000v Uninterruptible Power
System |
|
HP R3000v UPS
NOTE: The R3000v is available in
China and India only. |
AF444A |
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13129_div/13129_div.html
(Worldwide) |
|
HP Rack-Mountable R5500 UPS |
|
HP R5500 VA UPS, INTL |
AF416A |
HP R5500 VA UPS, NA/JPN |
AF426A |
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/11871_div/11871_div.html
(Worldwide)
NOTE: For additional information on HP Uninterruptable Power Systems
please go to: www.hp.com/servers/rackups. |
|
|
HP Monitored Power Distribution Unit (PDU)
|
HP Monitored Power Distribution
Unit: Full Rack Version |
|
HP 17.3 kVA S2324 Monitored PDU-
dual input, 3Ø, 24A (NA/JPN) |
AF503A
|
HP 8.6 kVA S1324 Monitored PDU-
single input, 3Ø, 24A (NA/JPN) |
AF504A
|
HP 16.6 kVA S2140 Monitored PDU-
dual input, 1Ø, 40A (NA/JPN) |
AF505A
|
HP 8.3 S1140 Monitored PDU- single
input, 1Ø, 40A (NA/JPN) |
AF506A |
HP 22.1 kVA S2316 Monitored PDU-
dual input, 3Ø, 16A (INTL) |
AF507A |
HP 11 kVA S1316 Monitored PDU-
single input, 3Ø, 16A (INTL) |
AF508A |
HP 14.7 kVA S2132 Monitored PDU-
dual input, 1Ø, 32A (INTL) |
AF509A |
HP 7.3 kVA S1132 Monitored PDU-
single input, 1Ø, 32A (INTL) |
AF510A |
HP Monitored Power Distribution
Unit: Half Rack Version |
|
HP 4.9 kVA S124 Monitored PDU-
single input, 1Ø, 24A (NA/JPN) |
AF914A |
HP 7.3 kVA S132 Monitored PDU-
single input, 1Ø, 32A (INTL) |
AF915A |
NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/12118_div/12118_div.html
(Worldwide) |
|
|
Modular PDUs 1U/0U
(Up to 28 outlets)
NOTE: 1U/0U mounting brackets shipped
with
the unit (optimized for 10000 and 9000 series racks).
|
Fixed Cord Extension Bars
NOTE: Two extension bar sticks; each
with (7) C13 plugs. |
351655-B21
|
3.6kVA Model - mPDU, 16A, High
(WW) |
252663-B24
|
2.8 kVA Model - mPDU, 24A, Low
(NA/JPN) |
252663-D71
|
4.9kVA Model - mPDU, 24A, High
(NA/JPN) |
252663-D72 |
7.3kVA Model - mPDU, 32A, High
(INT'L) |
252663-B31 |
8.3kVA Model - mPDU, 40A, High
(WW) |
252663-B21 |
8.3kVA Model - mPDU, 40A, High
(power cord attached) (NA/JPN) |
252663-D73 |
9.2kVA Model - mPDU, 40A, High
(power cord attached) (INTL) |
252663-B32 |
NOTE: For additional
information on HP Power Distribution Units including accessories please
go to: www.hp.com/go/pdu (Worldwide) |
|
|
HP Rack 10000 G2 Series
(Carbon/Graphite Metallic)
|
10642 G2 (42U) Rack Cabinet 1200mm
Deep - Shock Pallet |
AF034A
|
10642 G2 (42U) Rack Cabinet 1200mm
Deep - Pallet |
AF038A
|
10647 G2 (47U) Rack Cabinet 1200mm
Deep - Shock Pallet |
AF044A
|
10647 G2 (47U) Rack Cabinet 1200mm
Deep - Pallet |
AF045A
|
NOTE: It is mandatory
to use a shock pallet when shipping racks with equipment installed. |
|
NOTE: Please see
the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html
(Worldwide) |
|
NOTE: For additional
information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
|
|
HP KVM Switch Options |
2x1x16 IP Console Switch with
Virtual Media |
AF601A
|
4x1x16 IP Console Switch with
Virtual Media |
AF602A
|
2x16 Server Console Switch with
Virtual Media |
AF600A
|
HP Server Console Switch (KVM),
0 x 2 x 8 port |
AF616A
|
HP Server Console Switch (KVM),
0 x 2 x 16 port |
AF617A
|
HP 1x4 Console Switch |
AF611A
|
HP USB Server Console Cable, 6
foot, 2-Pack
NOTE: required for supporting USB
peripherals. |
AF613A
|
NOTE: Cat5e cables
are required to connect Interface Adapters to Console Switches. Cat5e cables
can be found at the following URL: http://www.hp.com/go/kvm. |
|
|
HP Serial Console Server
Options |
HP 16 Port Serial Console Server
(worldwide) |
AF101A
|
HP 48 Port Serial Console Server
(worldwide) |
AF102A
|
Serial Adapter, RJ45-D89 DCE Female,
1-pack |
AF103A
|
Serial Adapter, RJ45-D89 DCE Female,
8-pack |
AF110A
|
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. |
|
|
USB Options |
USB 1.44-MB External Diskette
Drive |
DC141B
|
USB Floppy Drive |
DC361B
|
HP USB-P/S2 Mouse |
DC369A
|
HP Keyboard (USB) standard 2004 |
DT528A#xxx |
|
Service
and Support Offerings
(HP Care Pack Services) |
Hardware Services 4-Hour On-site
Service |
|
13-Hour x 5-Day Coverage, 3 Years,
Electronic |
U9509E
|
24-Hour x 7 Day Coverage, 3 Years,
Electronic |
U9510E
|
Hardware Services Next Business
Day On-Site Service |
|
9-Hour x 5-Day Coverage, 3 Years, Electronic
|
U9508E
|
Hardware Services 6-Hour Call
to Repair On-Site Service |
|
Hardware Installation, Electronic |
U9520E
|
NOTE: For more
information, customer/resellers can contact: http://www.hp.com/services/carepack |
|
Memory
HP ProLiant DL160
G6 (all models) |
NOTE:
Memory configurations listed do not apply to "Factory Integrated Models". |
Standard Memory
4GB (2x2GB) or 6GB (3 x 2GB) depending on model, PC3-10600E Unbuffered UDIMM
memory, with ECC.
Maximum Memory
Up to 144GB memory is available with the optional installation of PC3-10600R
or PC3-8500R 8GB Registered RDIMM memory kits. |
NOTE:
Charts do not represent all possible memory configurations. |
DDR3 memory population guidelines
NOTE: For detailed memory
configuration rules and guidelines, please use the Online DDR3 Memory
Configuration Tool: www.hp.com/go/ddr3memory-configurator
Some DIMM installation guidelines are summarized below:
- For servers with eighteen (18) memory slots:
- There are three (3) channels per processor; six
(6) channels per server
- There are three (3) DIMM slots for each memory
channel; eighteen (18) total slots
- Memory channel 1 consists of the three (3) DIMMs
that are closest to the processor
- Memory channel 3 consists of the three (3) DIMMs
that are furthest from the processor
- DIMM slots that are white should be populated first
- Do not mix Unbuffered memory (UDIMMs) with Registered
memory (RDIMMs)
- Do not install DIMMs if the corresponding processor
is not installed
- If only one processor is installed in a 2CPU system,
only half of the DIMM slots are available
- To maximize performance, balance the total memory
capacity between all installed processors
- It is not required, but it is recommended to load
the channels similarly if possible
- You can only have up to eight (8) ranks installed
per channel
- You can only install two quad-rank DIMMs per channel
- You can only install two UDIMMs per channel; if available,
the third slot in the channel must remain empty
- Populate DIMMs from heaviest load (quad-rank) to
lightest load (single-rank) within a channel
- Heaviest load (DIMM with most ranks) within a channel
goes furthest from the chipset
- For memory mirroring mode, channel 3 must be unpopulated.
Channels 1 and 2 are populated identically
- For lock-step mode, channel 3 must be unpopulated.
DIMMs in channels 1 and 2 will be installed in pairs. The paired slots
will be 1,4; 2,5; 3;6 on a 3DPC system or 1,3; 2,4; on a 2DPC system
- No mixing DIMM voltage; all DIMMs must be the same
voltage
|
DIMM Type -> |
Registered
DIMMs (RDIMMs) |
Unbuffered
with ECC DIMMs (UDIMMs) |
DIMM Rank -> |
Dual Rank
(2R) |
Quad Rank (4R) |
Single Rank (1R) |
Dual Rank (2R) |
DIMM Capacity -> |
2GB |
4GB |
8GB |
8GB |
4GB |
1GB |
2GB |
DIMM Native Speed (MHz) -> |
1333 |
1333 |
1066 |
1333 |
1066 |
1333 |
1333 |
|
|
|
|
|
|
|
|
SLOTS THAT CAN BE POPULATED |
18 slot servers |
18 |
18 |
18 |
18 |
12 |
12 |
12 |
|
|
|
|
|
|
|
|
MAXIMUM CAPACITY (GB) |
18 slot servers |
36 |
72 |
144 |
144 |
48 |
12 |
24 |
|
|
|
|
|
|
|
|
POPULATED DIMM SPEED (MHz) |
1 DIMM Per Channel |
1333 |
1333 |
1066 |
1333 |
1066 |
1333 |
1333 |
2 DIMM Per Channel |
1066 |
1066 |
1066 |
1333* |
800 |
1066 |
1066 |
3 DIMM Per Channel |
800 |
800 |
800 |
800 |
not
supported
|
not
supported |
not
supported |
* - supported
with ROM update via ROM Based Setup Utility (RBSU). |
|
NOTES:
- Mixing DIMM speeds is allowed, but the system processor speed rules
always override the DIMM capabilities
- If you do mix DIMM speeds, the memory bus will default to the minimum
clock rate of all DIMMs in the system - even if the slower DIMM is on
the other processor
- If you install 1x 1066MHz DIMM in channel 1 and 1x 1333MHz DIMM in
channel 2, you still run at 1066MHz
- If you install 1x 1066MHz DIMM in channel 1 and 5x 1333MHz DIMMs with
1 DIMM Per Channel (DPC) in each of the other channels, you run at 1066MHz
- If you install 3DPC in one channel (if applicable) and 1DPC in all
other channels, you run at 800MHz
- 95 Watt CPU's are required for 1333MHz DIMM speeds. All other CPU's
are capable of up to 1066MHz
- References to the above MHz speeds are for the various speeds of DDR3
DIMMs; 1333 refers to DDR3-1333, etc.
|
|
DIMM slot and configuration diagrams
Basic memory slot & population diagram
- Population order; start with "A" first, "B" second,
"C" third, etc.
|
18
DIMM SLOTS (9 per CPU node) |
|
CPU1 |
CPU2 |
|
|
slot # |
population order |
slot # |
population order |
|
Chnl 1 |
1 |
G |
1 |
G |
Chnl 1 |
2 |
D |
2 |
D |
3 |
A |
3 |
A |
|
|
|
|
|
|
Chnl 2 |
4 |
H |
4 |
H |
Chnl 2 |
5 |
E |
5 |
E |
6 |
B |
6 |
B |
|
|
|
|
|
|
Chnl 3 |
7 |
I |
7 |
I |
Chnl 3 |
8 |
F |
8 |
F |
9 |
C |
9 |
C |
|
|
Standard memory configuration (1 CPU model)
- 6GB, consisting of three (3) 2GB dual-rank PC3-10600 RDIMMs
|
|
CPU1 |
CPU2 |
|
|
slot # |
population order |
slot # |
population order |
|
Chnl 1 |
1 |
G; empty |
1 |
G; empty |
Chnl 1 |
2 |
D; empty |
2 |
D; empty |
3 |
A; 2GB DIMM |
3 |
A; empty |
|
|
|
|
|
|
Chnl 2 |
4 |
H; empty |
4 |
H; empty |
Chnl 2 |
5 |
E; empty |
5 |
E; empty |
6 |
B; 2GB DIMM |
6 |
B; empty |
|
|
|
|
|
|
Chnl 3 |
7 |
I; empty |
7 |
I; empty |
Chnl 3 |
8 |
F; empty |
8 |
F; empty |
9 |
C; 2GB DIMM |
9 |
C; empty |
|
|
Standard memory plus optional memory (1 CPU model)
- 54GB, consisting of three (3) 2GB RDIMMs plus six (6) 8GB RDIMMs
- 3x 2GB dual-rank PC3-10600 RDIMMs
- 6x 8GB dual-rank PC3-10600 or PC3-8500 RDIMMs
|
|
CPU1 |
CPU2 |
|
|
slot # |
population order |
slot # |
population order |
|
Chnl 1 |
1 |
G; 8GB DIMM |
1 |
G; empty |
Chnl 1 |
2 |
D; 8GB DIMM |
2 |
D; empty |
3 |
A; 2GB DIMM |
3 |
A; empty |
|
|
|
|
|
|
Chnl 2 |
4 |
H; 8GB DIMM |
4 |
H; empty |
Chnl 2 |
5 |
E; 8GB DIMM |
5 |
E; empty |
6 |
B; 2GB DIMM |
6 |
B; empty |
|
|
|
|
|
|
Chnl 3 |
7 |
I; 8GB DIMM |
7 |
I; empty |
Chnl 3 |
8 |
F; 8GB DIMM |
8 |
F; empty |
9 |
C; 2GB DIMM |
9 |
C; empty |
|
|
Standard memory replaced with optional memory (1 CPU model)
RDIMM maximum configuration
- 72GB, consisting of nine (9) 8GB dual-rank PC3-10600 or PC3-8500 RDIMMs
|
|
CPU1 |
CPU2 |
|
|
slot # |
population order |
slot # |
population order |
|
Chnl 1 |
1 |
G; 8GB DIMM |
1 |
G; empty |
Chnl 1 |
2 |
D; 8GB DIMM |
2 |
D; empty |
3 |
A; 8GB DIMM |
3 |
A; empty |
|
|
|
|
|
|
Chnl 2 |
4 |
H; 8GB DIMM |
4 |
H; empty |
Chnl 2 |
5 |
E; 8GB DIMM |
5 |
E; empty |
6 |
B; 8GB DIMM |
6 |
B; empty |
|
|
|
|
|
|
Chnl 3 |
7 |
I; 8GB DIMM |
7 |
I; empty |
Chnl 3 |
8 |
F; 8GB DIMM |
8 |
F; empty |
9 |
C; 8GB DIMM |
9 |
C; empty |
|
|
UDIMM maximum configuration (1 CPU model)
- 12GB, consisting of six (6) 2GB dual-rank PC3-10600 UDIMMs
|
|
CPU1 |
CPU2 |
|
|
slot # |
population order |
slot # |
population order |
|
Chnl 1 |
1 |
G; empty |
1 |
G; empty |
Chnl 1 |
2 |
D; 2GB DIMM |
2 |
D; empty |
3 |
A; 2GB DIMM |
3 |
A; empty |
|
|
|
|
|
|
Chnl 2 |
4 |
H; empty |
4 |
H; empty |
Chnl 2 |
5 |
E; 2GB DIMM |
5 |
E; empty |
6 |
B; 2GB DIMM |
6 |
B; empty |
|
|
|
|
|
|
Chnl 3 |
7 |
I; empty |
7 |
I; empty |
Chnl 3 |
8 |
F; 2GB DIMM |
8 |
F; empty |
9 |
C; 2GB DIMM |
9 |
C; empty |
|
|
Standard memory replaced with optional memory (2 CPU model)
RDIMM maximum configuration
- 144GB, consisting of eighteen (18) 8GB PC3-10600 or PC3-8500 RDIMMs
|
|
CPU1 |
CPU2 |
|
|
slot # |
population order |
slot # |
population order |
|
Chnl 1 |
1 |
G; 8GB DIMM |
1 |
G; 8GB DIMM |
Chnl 1 |
2 |
D; 8GB DIMM |
2 |
D; 8GB DIMM |
3 |
A; 8GB DIMM |
3 |
A; 8GB DIMM |
|
|
|
|
|
|
Chnl 2 |
4 |
H; 8GB DIMM |
4 |
H; 8GB DIMM |
Chnl 2 |
5 |
E; 8GB DIMM |
5 |
E; 8GB DIMM |
6 |
B; 8GB DIMM |
6 |
B; 8GB DIMM |
|
|
|
|
|
|
Chnl 3 |
7 |
I; 8GB DIMM |
7 |
I; 8GB DIMM |
Chnl 3 |
8 |
F; 8GB DIMM |
8 |
F; 8GB DIMM |
9 |
C; 8GB DIMM |
9 |
C; 8GB DIMM |
|
|
UDIMM maximum configuration (2 CPU model)
- 24GB, consisting of twelve (12) 2GB dual-rank PC3-10600 UDIMMs
|
|
CPU1 |
CPU2 |
|
|
slot # |
population order |
slot # |
population order |
|
Chnl 1 |
1 |
G; empty |
1 |
G; empty |
Chnl 1 |
2 |
D; 2GB DIMM |
2 |
D; 2GB DIMM |
3 |
A; 2GB DIMM |
3 |
A; 2GB DIMM |
|
|
|
|
|
|
Chnl 2 |
4 |
H; empty |
4 |
H; empty |
Chnl 2 |
5 |
E; 2GB DIMM |
5 |
E; 2GB DIMM |
6 |
B; 2GB DIMM |
6 |
B; 2GB DIMM |
|
|
|
|
|
|
Chnl 3 |
7 |
I; empty |
7 |
I; empty |
Chnl 3 |
8 |
F; 2GB DIMM |
8 |
F; 2GB DIMM |
9 |
C; 2GB DIMM |
9 |
C; 2GB DIMM |
|
|
NOTE: Capacity references are rounded to the common Gigabyte values.
- 1GB = 1024MB
- 2GB = 2048MB
- 4GB = 4096MB
- 8GB = 8192MB
|
Following are memory
options available from HP: |
Memory |
Registered DIMMs (RDIMMs) |
|
HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21 |
HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21 |
HP 4GB 4Rx8 PC3-8500R-7 LP Kit |
500660-B21 |
HP 8GB 2Rx4 PC3-10600R-9 Kit |
500662-B21 |
HP 8GB 2Rx4 PC3-8500R-7 Kit |
516423-B21 |
Unbuffered with ECC DIMMs (UDIMMs) |
|
HP 1GB 1Rx8 PC3-10600E-9 Kit |
500668-B21 |
HP 2GB 2Rx8 PC3-10600E-9 Kit |
500670-B21 |
NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information
on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-evnergy-efficient |
|
Storage
|
1-4
|
Four Non-hot plug SATA or four
3.5" Hot-plug SAS/SATA hard drive bays |
A |
Optional DVD-ROM, or DVD RW |
 |
1-8 |
Eight Hot-plug SATA/SAS hard drive
bays |
A |
Optional DVD-ROM, or DVD RW |
| Drive
Support |
| |
Quantity Supported |
Position Supported |
Controller |
Removable Media |
|
| |
DVD-ROM |
Up to 1
|
A
|
Integrated IDE (ATAPI) (optional) |
DVD RW |
Up to 1
|
A
|
Integrated IDE (ATAPI) (optional) |
|
Hard Drives
NOTE: Transfer rates of drives are
dependent on the maximum transfer rate supported by the HBA or Controller.
Refer to the HBA or Controller technical specifications for details. |
SATA Non-Hot Plug
Midline (MDL) Drives 3.5" |
|
Quantity
Supported
|
Position
Supported
|
Controller |
250GB 3G SATA 7.2K
500GB 3GSATA 7.2K
750GB 3G SATA 7.2K |
Up to 4
|
1-4
|
HP Embedded SATA RAID Controller
NOTE: Transfer rate: 1.5 Gb/s SATA |
SATA Non-Hot Plug
Entry (ETY) Drives 3.5" |
|
Quantity
Supported
|
Position
Supported
|
Controller |
160GB 3G SATA 7.2K |
Up to 4
|
1-4
|
HP Embedded SATA RAID Controller
NOTE: Transfer rate: 1.5 Gb/s SATA |
SATA Hot Plug Midline
(MDL) Drives 3.5" |
|
Quantity
Supported
|
Position
Supported
|
Controller |
160GB 3G SATA 7.2K
250GB 3G SATA 7.2K
500GB 3G SATA 7.2K
750GB 3G SATA 7.2K
1TB 3G SATA 7.2K |
Up to 4
|
1-4
|
HP Smart Array P212Controller
HP Smart Arrays P410Controller
NOTE: Transfer rates up to 1.5 Gb/s |
SATA Non-Hot Plug
Entry (ETY) Drives 3.5" |
|
Quantity
Supported
|
Position
Supported
|
Controller |
160GB 3G SATA 7.2K
250GB 3G SATA 5.4K
120GB 3G SATA 5.4K |
Up to 4
|
1-4
|
HP Embedded SATA RAID Controller
NOTE: Transfer rate: 1.5 Gb/s SATA |
SAS Hot Plug 3.5"
Midline (MDL) Drives |
|
Quantity
Supported
|
Position
Supported
|
Controller |
1TB 3G 7.2K
750 3G 7.2K |
Up to 4
|
1-4
|
HP Smart Array P212Controller
HP Smart Arrays P410Controller
NOTE: Support for transfer rates
up to 3 Gb/s |
SAS Hot Plug 3.5"
Enterprise (ENT) Drives |
|
Quantity
Supported
|
Position
Supported
|
Controller |
72GB 3G 15K
146GB 6G 15K
146GB 3G 15K
300GB 6G 15K
300GB 3G 15K
450GB 3G 15K
400GB 3G 10K |
Up to 4
|
1-4
|
HP Smart Array P212Controller
HP Smart Array P410Controller
NOTE: Support for transfer rates
up to 3 Gb/s |
|
External Storage
|
|
Quantity
Supported
|
Position
Supported
|
Host Controller or Adapter
|
20 Modular Smart Array |
Up to 2 per SA-6402
Up to 4 per SA-6404
|
External
|
HP Smart Array P212/256MB
Controller
HP Smart Array P212/256MB Controller
HP Smart Array P411/256MB Controller |
50 Modular Smart Array |
Up to 2
|
External
|
60 HP StorageWorks Modular Smart
Array |
Up to 8
|
External
|
70 HP StorageWorks Modular Smart
Array |
Up to 8 |
External |
|
Tape and Disk-Based
Backup |
NOTE: For a complete listing of compatible
tape and disk-based backup offerings, please visit: http://www.hp.com/go/connect.
|
|
Position
Supported
|
Controller
|
Controller/HBA Option Kit Part Number
|
HP StorageWorks SCSI Tape Drives,
External
LTO-1 Ultrium 232
LTO-2 Ultrium 448
LTO-3 Ultrium 920
LTO-3 Ultrium 960
LTO4 Ultrium 1760
LTO-4 Ultrium 1840
DAT 40
DAT 72
DAT 160
1U Rack-Mount Kit
3U Rack-Mount Kit |
External
|
HP SC11Xe Host Bus Adapter |
412911-B21
|
|
|
|
|
HP StorageWorks USB Tape Drives,
External
DAT 40 USB
DAT 72 USB
DAT 160 USB
1U USB Rack-Mount Kit |
External
|
USB 2.0 Port |
N/A
|
|
|
|
|
HP StorageWorks SAS Tape Drives,
External
DAT 160 SAS
LTO-2 Ultrium 448 SAS
LTO-3 Ultrium 920 SAS
LTO-4 Ultrium 1760 SAS
LTO-4 Ultrium 1840 SAS
1U Rack-Mount Kit
3U Rack-Mount Kit |
External
|
HP Smart Array P212/Zero Memory
(ZM) Controller
HP Smart Array P411/256MB Controller |
462828-B21
462830-B21
|
|
|
|
|
HP StorageWorks SCSI Tape Automation,
External
DAT 72x10 Autoloader
1/8 G2 Autoloader
MSL2024
MSL4048 |
External
|
HP SC11Xe Host Bus Adapter
HP U320e SCSI Host Bus Adapter
NOTE: Recommended for MSL tape libraries. |
412911-B21
AH627A
|
|
|
|
|
HP StorageWorks SAS Tape Automation,
External
1/8 G2 Autoloader
MSL2024
MSL4048 |
External
|
HP Smart Array P212/Zero Memory
(ZM) Controller
HP Smart Array P411/256MB Controller |
462828-B21
462830-B21
|
|
|
|
|
HP StorageWorks Fibre Tape Automation,
External
MSL2024
MSL4048
MSL8096
MSL6000 |
External
|
Please consult the EBS
connectivity matrix at: http://www.hp.com/go/ebs
for detailed connectivity information. |
N/A
|
|
|
|
|
HP StorageWorks RDX Removable
Disk Backup System, External
RDX160
RDX320
RDX500 |
External |
USB 2.0 port |
N/A |
|
|
|
|
HP StorageWorks D2D Backup Systems
D2D120
D2D130
D2D2503i
D2D4004i |
External
|
Embedded Network Controller |
N/A
|
Power Specifications
HP 500W Power Supply
Part Number - AC 460W PSU |
515915-B21
Option Kit |
Input Voltage Range (Vrms) |
100 to 240 |
Frequency Range (Nominal) (Hz) |
47/63 |
Nominal Input Voltage (Vrms) |
100 |
120 |
200 |
220 |
230 |
240 |
Maximum Rated Output Wattage |
500 |
500 |
500 |
500 |
500 |
500 |
Nominal Input Current (A rms) |
5.74 |
4.99 |
2.86 |
2.58 |
2.46 |
2.36 |
Max Rated Input Wattage Rating (Watts) |
568 |
568 |
562 |
556 |
556 |
556 |
Max. Rated VA (Volt-Amp) |
574 |
574 |
573 |
567 |
567 |
567 |
Efficiency (%) at Max. Rated Output
Wattage |
88 |
88 |
89 |
90 |
90 |
90 |
Power Factor |
0.99 |
0.99 |
0.98 |
0.98 |
0.98 |
0.98 |
Leakage Current (mA) |
0.42 |
0.50 |
0.81 |
0.91 |
0.95 |
1.00 |
Max. Inrush Current (A peak) |
30 |
30 |
30 |
30 |
30 |
30 |
Max. Inrush Current duration (mS) |
20 |
20 |
20 |
20 |
20 |
20 |
Maximum British Thermal Unit Rating
(BTU-Hr) |
|
|
|
|
|
|
|
|
HP 460W Power Supply
Part Number - AC 460W PSU |
503296-B21
Option Kit |
Input Voltage Range (Vrms) |
100 to 240 |
Frequency Range (Nominal) (Hz) |
50/60 |
Nominal Input Voltage (Vrms) |
100 |
120 |
200 |
208 |
220 |
230 |
240 |
Maximum Rated Output Wattage |
460 |
460 |
460 |
460 |
460 |
460 |
460 |
Nominal Input Current (A rms) |
5.5 |
4.5 |
2.6 |
2.5 |
2.4 |
2.3 |
2.2 |
Max Rated Input Wattage Rating (Watts) |
526 |
520 |
505 |
505 |
503 |
503 |
503 |
Max. Rated VA (Volt-Amp) |
548 |
542 |
527 |
527 |
524 |
524 |
524 |
Efficiency (%) at Max. Rated Output
Wattage |
87.5 |
88.5 |
91 |
91 |
91.5 |
91.5 |
91.5 |
Power Factor |
0.97 |
0.97 |
0.97 |
0.97 |
0.97 |
0.97 |
0.97 |
Leakage Current (mA) |
0.42 |
0.50 |
0.83 |
0.87 |
0.92 |
0.96 |
1.00 |
Max. Inrush Current (A peak) |
30 |
30 |
30 |
30 |
30 |
30 |
30 |
Max. Inrush Current duration (mS) |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
Maximum British Thermal Unit Rating
(BTU-Hr) |
1794 |
1773 |
1725 |
1725 |
1715 |
1715 |
1715 |
|
|
HP 750W Power Supply
Part Number - AC 750W PSU |
512327-B21
Option Kit |
Input Voltage Range (Vrms) |
100 to 240 |
Frequency Range (Nominal) (Hz) |
50/60 |
Nominal Input Voltage (Vrms) |
100 |
120 |
200 |
208 |
220 |
230 |
240 |
Max Rated Output Wattage Rating |
750 |
750 |
750 |
750 |
750 |
750 |
750 |
Nominal Input Current (A rms) |
8.9 |
7.4 |
4.3 |
4.1 |
3.9 |
3.7 |
3.6 |
Max Rated Input Wattage Rating (Watts) |
857 |
847 |
824 |
825 |
820 |
820 |
820 |
Max. Rated VA (Volt-Amp) |
894 |
884 |
859 |
859 |
854 |
854 |
854 |
Efficiency (%) at Max. Rated Output
Wattage |
87.5 |
88.5 |
91 |
91 |
91.5 |
91.5 |
91.5 |
Power Factor |
0.97 |
0.97 |
0.97 |
0.97 |
0.97 |
0.97 |
0.97 |
Leakage Current (mA) |
0.42 |
0.50 |
0.83 |
0.87 |
0.92 |
0.96 |
1.00 |
Max. Inrush Current (A peak) |
30 |
30 |
30 |
30 |
30 |
30 |
30 |
Max. Inrush Current duration (mS) |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
Maximum British Thermal Unit Rating
(BTU-Hr) |
2925 |
2892 |
2812 |
2812 |
2797 |
2797 |
2797 |
|
System Specifications
Power |
|
|
ProLiant DL160 G6 Fully Configured |
115V/60Hz |
220V/50Hz |
Fully Loaded System Input Wattage
(W) |
448 |
445 |
Fully Loaded System Input Current
(A rms) |
3.833 |
2.046 |
Fully Loaded System Thermal
(BTU- Hr) |
1529 |
1518 |
Fully Loaded System VA (Volt-Amp) |
449 |
454 |
System Inrush Current with all power
supplies loaded (A) |
10.1 |
10.96 |
Power cord requirements |
Nema 5-15P to IEC320-C13 |
IEC320-C13 to IEC320-C14 |
NOTE: Power
shown is for a fully configured system consisting of (2) CPU, (8)
double-sided DIMMs, (2) HDDs, (1) CD-ROM, and (2) PCI cards. |
Power Cord |
AF556A |
|
|
Server Power Cords |
One 6' Highline (IEC-IEC) power
cord ships standard
NOTE: HP ProLiant DL servers no longer
ship standard with NEMA power cords (163719-002) that allow connection to
110V US wall outlets in a home or office. ProLiant DL servers are primarily
connected to PDU's in data center racks so they now ship standard with only
a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server
using a 110V receptacle (NEMA-15), the NEMA power cord (227099-001) must
be ordered separately.
If customers require a local power cord, they can check the power cord matrix
for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix. |
Technical Specifications
System Unit |
Dimensions (H x W x D)
(with bezel) |
1.70 x 17.64 x 26.85
in (4.32 x 44.80 x 68.20 cm) |
Weight
(approximate) |
Maximum
(all hard drives, power supplies, and processors installed) |
34.00 lb (16.78 kg) |
Minimum
(one hard drive, power supply, and processor installed) |
28.00 lb (12.7 kg) |
Input Requirements
(per power supply) |
Rated Line Voltage |
90 to 132 VAC
180 to 264 VAC |
Rated Input Current |
5. 8 Amps (at 100
VAC) to 2.9 Amps (at 200 VAC) |
Rated Input Frequency |
47 to 63 Hz |
BTU Rating |
Rated Input Power |
570W (at 100 VAC)
565W (at 200 VAC) |
Maximum |
500W |
1940 BTU / hr (at 100 VAC)
1920 BTU/hr (at 200 VAC) |
460W |
1773 BTU / hr (at 120 VAC)
1715 (at 240 VAC) |
750W |
2892 BTU / hr (at 120 VAC)
2797 (at 240 VAC) |
Power Specifications |
To review typical
system power ratings use the Power Advisor which is available via the online
tool located at URL:
www.hp.com/go/proliant-energy-efficient
Or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL160 G6
- Follow the instructions of the next screens. |
Power Supply Output
(per power supply) |
Rated Steady-State Power |
500 Watts (at 100
VAC),
500 Watts (at 200 VAC) |
Maximum Peak Power
(See Power Specifications Tables) |
500Watts (at 100 VAC),
500 Watts (at 200 VAC) |
System Inlet Temperature |
Operating |
10° to 35°C
(50° to 95°F) at sea level with an altitude derating of 1.0°C
per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be limited by the type
and number of options installed.
System performance may be reduced if operating with a fan fault or above
30°C (86°F). |
Non-operating |
-30° to 60°C
(-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). |
Relative Humidity
(non-condensing) |
Operating |
10 to 90% relative
humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. |
Non-operating |
-30° to 60°C
(-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). |
Altitude |
Operating |
3050 m (10,000 ft).
This value may be limited by the type and number of options installed. Maximum
allowable altitude change rate is 457 m/min (1500 ft/min). |
Non-operating |
9144 m (30,000 ft).
Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
Acoustic Noise |
Listed are the declared
A-Weighted sound power levels (LWAd) and declared average bystander position
A-Weighted sound pressure levels (LpAm) when the product is operating in
a 23°C ambient environment. Noise emissions were measured in accordance
with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). |
Idle |
|
LWAd
|
6.86 |
LpAm
|
52.36dBA |
Operating
|
|
LWAd
|
6.89 |
LpAm
|
52.60dBA |
Emissions Classification
(EMC) |
FCC Rating |
Class A |
Normative Standards |
CISPR 22; EN55022;
EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2;
EN 61000-3-3; EN 60950-1; IEC 60950-1 |
NOTE:
Product conformance to cited product specifications is based on sample (type)
testing, evaluation, or assessment. This product or family of products is
eligible to bear the appropriate compliance logos and statements. |
|
Non-Hot Plug SATA Hard Drives
|
160-GB 7.2K
458947-B21 |
Capacity |
160,041 MB |
Height |
1.028 in (2.61 cm) |
Width |
4.0 in (10.16 cm) |
Depth |
5.787 in (147.0 mm) |
Interface |
SATA ATA |
Transfer Rate Synchronous
(Maximum) |
1.5Gb/s |
Seek Time (typical
reads, including settling) |
Single Track |
0.9 ms |
Average |
9.0 ms |
Full-Stroke |
17.8 ms |
Rotational Speed |
7,200 rpm |
Physical Configuration |
Bytes/Sector |
512 |
Logical Blocks |
312,581,808 |
Operating Temperature |
41° to 131°
F (5° to 55° C) |
|
NC362i Integrated
Dual Port Gigabit Server Adapter |
Network Interface |
Integrated 10/100/1000BASE-T
Transceiver |
Combines a triple-speed
IEEE 802.3TM - Compliant Media Access Controller (MAC) with a triple-speed
Ethernet transceiver. |
Data Transfer Method |
Compliant to x1 PCIe
Specification |
Network Transfer Rate |
10Base-T (Half-Duplex) |
10 Mb/s |
10Base-T (Full-Duplex) |
20 Mb/s |
100Base-TX (Half-Duplex) |
100 Mb/s |
100Base-TX (Full-Duplex) |
200 Mb/s |
1000Base-TX (Half and Full-Duplex) |
2000Mb/s |
Connector |
RJ-45 connector |
Cable Support |
Performs all the physical
layer functions for 10BASE-T, 100BASE-T, and 1000BASE-T Ethemet on standard
Category 5 UTP |
|
Smart Array P410/410i Controller
|
Disk Drive and Enclosure
Interface |
3G SAS (Serial Attached SCSI) |
1.5G SATA (Serial ATA) |
SAS Connectors |
2 internal (Mini-SAS) x8 wide
port connectors |
Cache Memory Speed |
DDR2-533MHz with 40 or 72-bit
wide bus provides up to 4.2 GB/s maximum bandwidth. |
Server Interface |
x8 2.5G PCIe 2.0 provides 2GB/s
maximum bandwidth |
SAS Speed |
x8 3G SAS provides 2.4GB/s maximum
bandwidth |
Cache Memory |
40-bit 256MB ECC protected cache
(72-bit 512MB BBWC module upgrades available); transportable with battery-backed
upgrade |
Logical Drives Supported |
Up to 32 logical drives |
Host Memory Addressing |
64-bit, supporting greater than
4GB server memory space |
RAID Support |
RAID 6, 6+0 (Advanced Data Guarding)
NOTE: The minimum of 256 MB cache,
battery kit, and Smart Array Advanced Pack License Key upgrade is required
to enable RAID 6, 6+0 |
RAID 5, 5+0 (Distributed Data
Guarding)
NOTE: The 256 MB & Battery Kit
upgrade is required to enable RAID 5, 5+0 support of the Smart Array P410i |
RAID 1+0 (Striping & Mirroring) |
RAID 0 (Striping) |
|
Environment-friendly Products
and Approach |
End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go
to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will
be recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment
information for each product type for use by treatment facilities. This
information (product disassembly instructions) is posted on the Hewlett
Packard web site at: http://www.hp.com/go/green.
These instructions may be used by recyclers and other WEEE treatment facilities
as well as HP OEM customers who integrate and re-sell HP equipment.
|
|
© Copyright 2009 Hewlett-Packard Development Company,
L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation.
Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation
in the U.S. and other countries.
The only warranties for HP products and services are set forth in the
express warranty statements accompanying such products and services. Nothing
herein should be construed as constituting an additional warranty. HP
shall not be liable for technical or editorial errors or omissions contained
herein.
For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less.
|
 DA-13247 2 - Version 2 - April 27, 2009
| |